In Vitro and Ex Vivo Evaluation of a Novel Guided Drill System for Bone-Anchored Hearing Implants

Johansson, Martin L (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Eriksson, T. (författare)
Omar, Omar (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
 (creator_code:org_t)
Quintessence Publishing, 2019
2019
Engelska.
Ingår i: International Journal of Oral & Maxillofacial Implants. - : Quintessence Publishing. - 0882-2786. ; 34:6
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: The aim of this study was to evaluate a new guided drill system (MIPS) for placement of boneanchored hearing systems (BAHS) with respect to cutting performance, generation of heat, and distortion of the bone during drilling and compare it with a conventional drill system (Ponto). Further, the role of irrigation and drilling procedure with respect to the degree of heat generation was evaluated. Materials and Methods: Compact artificial bone was subjected to each drill in the two systems (conventional vs guided) while measuring thrust force, torque, and temperature. The temperature changes, induced during different drilling procedures, were measured by thermocouples positioned 0.5 mm from the periphery of the drill tract. The degree of bone damage was evaluated histologically after drilling in bovine, compact, tibial bone. Results: The mean thrust energy was significantly lower for the drills of the guided system compared with the corresponding conventional drills. In contrast, the mean torque energy was higher using the guided system but only for the initial guide drilling step. Whereas twist drills in combination with a guided drilling approach (MIPS) generated relatively more heat, especially during a prolonged drilling sequence, it was more forgiving in the case of impaired irrigation. The histologic evaluation showed relatively more even cut surfaces and fewer microcracks in the osteotomy wall using the guided system compared with the conventional system. Conclusion: Provided the clinically recommended drilling procedure was adhered to, the absolute temperatures using either a conventional drill system or a guided drill system were below the threshold for thermally induced tissue damage. This study suggests that the guided MIPS system conveys a promising design for an efficient and still-safe osteotomy site preparation for BAHS placement.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

BAHS
bone drilling
bone-anchored hearing system
bone-anchored
prosthesis
drill mechanics
flapless procedure
guide
heat generation
osteotomy
surgical guide
surgical procedure
heat-generation
site preparation
artificial bone
cortical bone
surgery
temperatures
single
force
Dentistry
Oral Surgery & Medicine

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Johansson, Marti ...
Eriksson, T.
Omar, Omar
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
International Jo ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy