SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/286864"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/286864" > Mean systemic filli...

Mean systemic filling pressure - from Guyton to the ICU, and back again

Möller, Per Werner (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för anestesiologi och intensivvård,Institute of Clinical Sciences, Department of Anesthesiology and Intensive care
 (creator_code:org_t)
ISBN 9789178332328
Göteborgs universitet, 2019
Engelska.
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Introduction: Mean systemic filling pressure (MSFP) is the equilibrated vascular pressure at zero flow. Venous return (VR) driving pressure (VRdP) is the difference between MSFP and right atrial pressure (RAP). In clinical research, MSFP can be estimated: MSFPinsp_hold is the zero-flow extrapolation of RAP-cardiac output data-pairs from inspiratory hold maneuvers; MSFPa is a dynamic analogue computed from clinically available hemodynamics. However, results are controversial and fundamental concepts of VR physiology are questioned. We aimed to test experimentally the concept of VRdP in dynamic conditions and validate estimates of MSFP against zero-flow measurements. Methods: We compared estimates of MSFP against zero-flow measurements from right atrial balloon occlusion (MSFPRAO), or from intermittently paused venoarterial extracorporeal membrane oxygenation (ECMO), in three porcine models exposed to changing blood volumes and vasoconstriction. Results: Changes in RAP resulted in immediate and directionally opposite changes in VR. Temporary VR and ECMO flow imbalance resulted in dynamically changing VRdP and RAP. In euvolemia, MSFP was increased by increased airway pressure. A moderate increase in positive end-expiratory pressure increased RAP, MSFPRAO and VRdP. Resistance to VR did not change. Changing blood volume led to concordant changes in RAP, MSFPRAO, VRdP and flow. Vasoconstriction and volume expansion increased MSFP and maximum achievable ECMO flow with similar effects on oxygen delivery. MSFPinsp_hold overestimated MSFPRAO in euvolemia due to flow restoration predominantly occurring in the inferior vena cava. Methods for MSFP estimation had an accuracy that was dependent on volume status. All methods tracked changes in the reference method concordantly. However, with the possible exception of MSFPa, the bias was clinically unacceptable. Conclusion: If pressure effects from volume shifts are accounted for, the concept of VRdP is valid also during dynamic conditions. VR physiology can explain the responses of volume expansion and vasoconstriction on venoarterial ECMO flow. Inspiratory hold maneuvers are unsuitable for the estimation of MSFP due to clinically significant bias.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)

Nyckelord

mean systemic filling pressure
venous return
right atrial pressure
positive pressure ventilation
extracorporeal membrane oxygenation

Publikations- och innehållstyp

vet (ämneskategori)
dok (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Möller, Per Wern ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinska och f ...
och Fysiologi
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy