Results at 3-year follow-up of totally extraperitoneal (TEP) hernia surgery with long-term resorbable mesh

Ruiz-Jasbon, Fernando (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för kirurgi,Institute of Clinical Sciences, Department of Surgery
Ticehurst, K. (författare)
Ahonen, J. (författare)
visa fler...
Norrby, Jonny, 1965 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för kirurgi,Institute of Clinical Sciences, Department of Surgery
Falk, Peter, 1962 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för kirurgi,Institute of Clinical Sciences, Department of Surgery
Ivarsson, Marie-Louise, 1956 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för kirurgi,Institute of Clinical Sciences, Department of Surgery
visa färre...
 (creator_code:org_t)
2020-01-10
2020
Engelska.
Ingår i: Hernia. - : Springer Science and Business Media LLC. - 1265-4906 .- 1248-9204. ; 24, s. 669-676
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • © 2020, The Author(s). Introduction: Synthetic non-resorbable mesh is almost standard in hernia surgery. However, several studies have showed negative effects of permanent implants such as chronic inflammation and complications involving different organs bordering the mesh. Such complications can raise the risk of chronic post-operative pain (CPP). Recently promising results regarding CPP have been published in patients with Lateral Inguinal Hernia (LIH) using a slowly resorbable mesh in Lichtenstein technique. For this reason the aim of the present study was to find the effect of a slowly resorbable implant on the long-term rate of hernia recurrence and chronic post-operative pain in patients with LIH repaired with TEP procedure. Methods: Prospective pilot study of TEP repair using TIGR® Matrix Surgical Mesh in 35 primary LIH. At 3-year follow-up the Visual Analogue Scale (VAS) and the Inguinal Pain Questionnaire were employed to assess pain. Recurrence was determined by ultrasound and clinical examination. Results: All patients completed the pain questionnaires but one patient did not attend the planned clinical examination for the 3-year follow-up. No patients had CPP, as defined in the World Guidelines for Groin Hernia Management. Almost all patients had lower VAS score in any activity 3years following surgery in comparison to the preoperative period. Three patients (8.8%) suffered symptomatic recurrence during the 3-year follow-up. Conclusion: TEP repair in patients with LIH using a synthetic long-term resorbable mesh was found to be encouraging respecting chronic post-operative pain at 3-year follow-up but at the cost of an increased risk of recurrence.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

Chronic pain
Implant
Inguinal hernia
Recurrence
Resorbable mesh
TEP

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Hernia (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy