False Positive Results in SARS-CoV-2 Serological Tests for Samples From Patients With Chronic Inflammatory Diseases

Kharlamova, N. (författare)
Karolinska Inst, Dept Clin Neurosci, Stockholm, Sweden.;Karolinska Inst, Ctr Mol Med, Stockholm, Sweden.
Dunn, N. (författare)
Karolinska Institutet
Bedri, S. K. (författare)
Karolinska Institutet
visa fler...
Jerling, S. (författare)
Karolinska Inst, Dept Clin Neurosci, Stockholm, Sweden.;Karolinska Inst, Ctr Mol Med, Stockholm, Sweden.
Almgren, M. (författare)
Karolinska Inst, Dept Clin Neurosci, Stockholm, Sweden.;Karolinska Inst, Ctr Mol Med, Stockholm, Sweden.
Faustini, F. (författare)
Karolinska Institutet
Gunnarsson, I. (författare)
Karolinska Institutet
Rönnelid, Johan (författare)
Uppsala universitet,Klinisk immunologi
Pullerits, Rille, 1969 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för reumatologi och inflammationsforskning,Institute of Medicine, Department of Rheumatology and Inflammation Research,Univ Gothenburg, Sahlgrenska Acad, Inst Med, Dept Rheumatol & Inflammat Res, Gothenburg, Sweden.;Sahlgrens Univ Hosp, Dept Clin Immunol & Transfus Med, Gothenburg, Sweden.
Gjertsson, Inger, 1962 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för reumatologi och inflammationsforskning,Institute of Medicine, Department of Rheumatology and Inflammation Research,Univ Gothenburg, Sahlgrenska Acad, Inst Med, Dept Rheumatol & Inflammat Res, Gothenburg, Sweden.
Lundberg, K. (författare)
Karolinska Institutet
Månberg, Anna, 1985- (författare)
KTH,Science for Life Laboratory, SciLifeLab,Affinitets-proteomik,KTH Royal Inst Technol, Div Affin Prote, Dept Prot Sci, SciLifeLab, Stockholm, Sweden.
Pin, Elisa (författare)
KTH,Affinitets-proteomik,Science for Life Laboratory, SciLifeLab,KTH Royal Inst Technol, Div Affin Prote, Dept Prot Sci, SciLifeLab, Stockholm, Sweden.
Nilsson, Peter (författare)
KTH,Science for Life Laboratory, SciLifeLab,Affinitets-proteomik,KTH Royal Inst Technol, Div Affin Prote, Dept Prot Sci, SciLifeLab, Stockholm, Sweden.
Hober, Sophia, Professor, 1965- (författare)
KTH,Proteinteknologi,KTH Royal Inst Technol, Dept Prot Sci, Stockholm, Sweden.
Fink, K. (författare)
Karolinska Institutet
Fogdell-Hahn, A. (författare)
Karolinska Institutet
visa färre...
Karolinska Institutet Karolinska Inst, Dept Clin Neurosci, Stockholm, Sweden;Karolinska Inst, Ctr Mol Med, Stockholm, Sweden. (creator_code:org_t)
2021-05-03
2021
Engelska.
Ingår i: Frontiers in Immunology. - : Frontiers Media SA. - 1664-3224. ; 12
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Patients with chronic inflammatory diseases are often treated with immunosuppressants and therefore are of particular concern during the SARS-CoV-2 pandemic. Serological tests will improve our understanding of the infection and immunity in this population, unless they tests give false positive results. The aim of this study was to evaluate the specificity of SARS-Cov-2 serological assays using samples from patients with chronic inflammatory diseases collected prior to April 2019, thus defined as negative. Samples from patients with multiple sclerosis (MS, n=10), rheumatoid arthritis (RA, n=47) with or without rheumatoid factor (RF) and/or anti-cyclic citrullinated peptide antibodies (anti-CCP2) and systemic lupus erythematosus (SLE, n=10) with or without RF, were analyzed for SARS-CoV-2 antibodies using 17 commercially available lateral flow assays (LFA), two ELISA kits and one in-house developed IgG multiplex bead-based assay. Six LFA and the in-house validated IgG assay correctly produced negative results for all samples. However, the majority of assays (n=13), gave false positive signal for samples from patients with RA and SLE. This was most notable in samples from RF positive RA patients. No false positive samples were detected in any assay using samples from patients with MS. Poor specificity of commercial serological assays could possibly be, at least partly, due to interfering antibodies in samples from patients with chronic inflammatory diseases. For these patients, the risk of false positivity should be considered when interpreting results of the SARS-CoV-2 serological assays.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Reumatologi och inflammation (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Rheumatology and Autoimmunity (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Immunologi inom det medicinska området (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Immunology in the medical area (hsv//eng)

Nyckelord

SARS-CoV-2
autoimmunity
autoantibodies
diagnostics
rheumatoid
arthritis
systemic lupus erythematosus
multiple sclerosis
rheumatoid
factor
rheumatoid-factor
molecular mimicry
revised criteria
classification
antibody
recommendations
validation
arthritis
smoking
assays
Immunology
SARS-CoV-2

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy