SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/306982"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/306982" > Characteristics of ...

Characteristics of Continuous Glucose Monitoring Metrics in Persons with Type 1 and Type 2 Diabetes Treated with Multiple Daily Insulin Injections

Hallström, Sara (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
Hirsch, I. B. (författare)
Ekelund, M. (författare)
visa fler...
Sofizadeh, S. (författare)
Albrektsson, H. (författare)
Dahlqvist, S. (författare)
Svensson, Ann-Marie, 1961 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
Lind, Marcus, 1976 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
visa färre...
 (creator_code:org_t)
Mary Ann Liebert Inc, 2021
2021
Engelska.
Ingår i: Diabetes Technology & Therapeutics. - : Mary Ann Liebert Inc. - 1520-9156 .- 1557-8593. ; 23:6, s. 425-433
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Although guidelines advocate similar continuous glucose monitoring (CGM) targets for insulin-treated persons with type 1 diabetes (T1D) and type 2 diabetes (T2D), it is unclear how these persons differ with respect to hypoglycemia, glucose variability, and other CGM metrics in clinical practice. Methods: We used data from 2 multicenter randomized-controlled trials (GOLD and MDI-Liraglutide) where 161 persons with T1D and 124 persons with T2D treated with multiple daily injections were included and monitored with masked CGM. Results: Persons from both cohorts had similar mean glucose levels, 10.9 mmol/L (196 mg/dL) in persons with T1D and 10.8 mmol/L (194 mg/dL) in persons with T2D. Time in hypoglycemia (<3.9 mmol/L [70 mg/dL]) was 5.1% and 1.0% for persons with T1D and T2D, respectively (P < 0.001). Corresponding estimates for the standard deviations of mean glucose levels were 4.4 mmol/L (79 mg/dL) versus 3.0 (54 mg/dL) (P < 0.001), for coefficient of variation 41% versus 28% (P < 0.001), and for time in range 38.2% versus 45.3%, respectively (P = 0.004). Mean C-peptide levels were 0.05 nmol/L and 0.67 nmol/L (P < 0.001) for persons with T1D and T2D, respectively. Conclusions: Persons with T1D compared with persons with T2D treated with multiple daily insulin injections spend considerably more time in hypoglycemia, have higher glucose variability, and less "time in range." This needs to be taken into account in daily clinical care and in recommended targets for CGM metrics.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Endokrinologi och diabetes (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Endocrinology and Diabetes (hsv//eng)

Nyckelord

Type 1 diabetes
Type 2 diabetes
Continuous glucose monitoring
Glucose
variability
Time in range
randomized clinical-trial
glycemic control
sensing technology
hypoglycemia
variability
liraglutide
multicenter
management
hba(1c)
range
Endocrinology & Metabolism

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy