Sökning: id:"swepub:oai:gup.ub.gu.se/308003" >
Prostate Cancer Dif...
Prostate Cancer Diffusion-Weighted Magnetic Resonance Imaging: Does the Choice of Diffusion-Weighting Level Matter?
-
- Maier, Stephan E, 1959 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
-
- Wallström, Jonas (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
-
- Langkilde, Fredrik, 1990 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
-
visa fler...
-
- Johansson, Jens (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
-
- Kuczera, Stefan (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
-
- Hugosson, Jonas, 1955 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för urologi,Institute of Clinical Sciences, Department of Urology
-
- Hellström, Mikael, 1950 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
-
visa färre...
-
(creator_code:org_t)
- 2021-09-18
- 2022
- Engelska.
-
Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1053-1807 .- 1522-2586. ; 55:3, s. 842-853
- Relaterad länk:
-
https://gup.ub.gu.se...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background Diffusion-weighted magnetic resonance imaging plays an important role in multiparametric assessment of prostate lesions. The derived apparent diffusion coefficient (ADC) could be a useful quantitative biomarker for malignant growth, but lacks acceptance because of low reproducibility. Purpose To investigate the impact of the choice of diffusion-weighting levels (b-values) on contrast-to-noise ratio and quantitative measures in prostate diffusion-weighted MRI. Study Type Retrospective and simulation based on published data. Subjects Patient cohort (21 men with Prostate Imaging-Reporting and Data System (PI-RADS) version 2 score >= 3) from a single-center study. Field Strength/Sequence 3 T/diffusion-weighted imaging with single-shot echo-planar imaging. Assessment Both clinical data and simulations based on previously acquired data were used to quantify the influence of b-value choice in normal peripheral zone (PZ) and PZ tumor lesions. For clinical data, ADC was determined for different combinations of b-values. Contrast-to-noise ratio and quantitative diffusion measures were simulated for a wide range of b-values. Statistical Tests Tissue ADC and the lesion-to-normal tissue ADC ratios of different b-value combinations were compared with paired two-tailed Student's t-tests. A P-value Findings about b-value dependence derived from clinical data and from simulations agreed with each other. Provided measurement was limited to two b-values, simulation-derived optimal b-value choices coincided with PI-RADSv2 recommendations. For two-point measurements, ADC decreased by 15% when the maximum b-value increased from 1000 to 1500 seconds/mm(2), but corresponding lesion-to-normal tissue ADC ratio showed no significant change (P = 0.86 for acquired data). Simulations with three or more measurement points produced ADCs that declined by only 8% over this range of maximum b-value. Corresponding ADC ratios declined between 2.6% (three points) and 3.8% (21 points). Simulations also revealed an ADC reduction of about 19% with the shorter echo and diffusion time evaluated. Data Conclusion The comprehensive assessment of b-value dependence permits better formulation of protocol and analysis recommendations for obtaining reproducible results in prostate cancer diffusion-weighted MRI. Level of Evidence 4 Technical Efficacy Stage 2
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cancer and Oncology (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Urologi och njurmedicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Urology and Nephrology (hsv//eng)
Nyckelord
- diffusion
- b-value
- apparent diffusion coefficient
- apparent diffusion
- coefficient ratio
- kurtosis
- prostate peripheral zone
- gleason score
- peripheral zone
- b-value
- mathematical-models
- coefficient values
- water diffusion
- mri
- tumor
- ratio
- time
- Radiology
- Nuclear Medicine & Medical Imaging
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas