SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/309378"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/309378" > Influence of implan...

Influence of implant geometry and osteotomy design on early bone healing: A pre-clinical in vivo study

Abrahamsson, Ingemar, 1953 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 2,Institute of Odontology, Section 2
Carcuac, Olivier, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 2,Institute of Odontology, Section 2
Berglundh, Tord, 1954 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 2,Institute of Odontology, Section 2
 (creator_code:org_t)
2021-08-14
2021
Engelska.
Ingår i: Clinical Oral Implants Research. - : Wiley. - 0905-7161 .- 1600-0501. ; 32:10, s. 1190-1199
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives To analyze the early stages of osseointegration around implants with different geometry following installation in sites using different osteotomy protocols. Materials and methods Two types of implants were installed using regular or modified (reduced diameter) osteotomy protocols in mandibular premolar/molar regions following tooth extraction in six dogs. Three implant site categories were created: Reference (A implant and regular osteotomy), Test-1 (B implant and regular osteotomy), and Test-2 (B implant and modified osteotomy). Implant installation procedures were repeated after 4 and 6 weeks. The insertion torque (ITQ) was measured during implant installation and resonance frequency analysis providing implant stability quotient (ISQ) values was performed following implant installation and once every week during the course of the study. Biopsies were obtained immediately after the 3rd installation procedure and prepared for histological analysis. Results The modified osteotomy protocol created a higher insertion torque (ITQ). The analysis also revealed a correlation between insertion torque at implant installation and radiographic bone loss after 6 weeks of healing. The decline in ISQ values during healing was more pronounced at Test-2 than other sites. While the degree of bone-to-implant contact (BIC%) in the marginal area was similar in test and reference sites at 6 weeks of healing, Test-2 implants presented with a significantly higher BIC% in the mid and apical areas than Test-1 implants. Conclusions It is suggested that placement of implants in undersized osteotomy sites will result in an increased remodeling of the cortical bone during the early healing process.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

animal experiments
bone implant interactions
imaging
periodontology
radiology
surgical techniques
early osseointegration
formation adjacent
stability
surfaces
torque
Dentistry
Oral Surgery & Medicine
Engineering

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Abrahamsson, Ing ...
Carcuac, Olivier ...
Berglundh, Tord, ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
Clinical Oral Im ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy