EVALUATION OF VGC ANALYZER BY COMPARISON WITH GOLD STANDARD ROC SOFTWARE AND ANALYSIS OF SIMULATED VISUAL GRADING DATA

Hansson, Jonny (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för medicinsk strålningsvetenskap,Institute of Clinical Sciences, Department of Medical Radiation Sciences
Månsson, Lars Gunnar, 1951 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för medicinsk strålningsvetenskap,Institute of Clinical Sciences, Department of Medical Radiation Sciences
Båth, Magnus, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för medicinsk strålningsvetenskap,Institute of Clinical Sciences, Department of Medical Radiation Sciences
 (creator_code:org_t)
2021-05-03
2021
Engelska.
Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 195:3-4, s. 378-390
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The purpose of the present work was to evaluate the use of resampling statistical methods for analysis of visual grading data-implemented in the software VGC Analyzer-by comparing the reanalyzed results from previously performed visual grading studies with the results calculated by gold standard receiver operating characteristic (ROC) methodology, Obuchowski-Rockette (OR)-Dorfman-Berbaum-Metz (DBM) multiple-readers and multiple-case (MRMC) and by analysis of simulated visual grading data where the true distribution was presumed to be known. The reanalysis was performed on two multiple-reader studies with non-paired data and paired data, respectively. The simulation study was performed by simulating a large number of visual grading characteristics (VGC) studies and by analyzing the statistical distribution of null hypothesis (H-0) rejection rate. The comparison with OR-DBM MRMC showed good agreement when analyzing non-paired data for both fixed-reader and random-reader settings for the calculated area under the curve values and the confidence intervals (CIs). For paired data analysis, VGC Analyzer showed significantly lower CIs compared with the ROC software. This effect was also illustrated by the simulation study, where the VGC Analyzer, in general, showed good accuracy for simulated studies with stable statistical basis. For simulated studies with unstable statistics, the accuracy in the H-0 rejection rate decreased. The present study has shown that resampling methodology can be used to accurately perform the statistical analysis of a VGC study, although the resampling technique used makes the method sensitive to small data sets.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

dorfman-berbaum-metz
image quality
statistical-analysis
chest
radiography
dose reduction
binormal model
multireader
accuracy
readers
Environmental Sciences & Ecology
Public
Environmental & Occupational
Health
Nuclear Science & Technology
Radiology
Medical Imaging

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hansson, Jonny
Månsson, Lars Gu ...
Båth, Magnus, 19 ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Radiation Protec ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy