EVALUATION OF TWO CHEST TOMOSYNTHESIS CYSTIC FIBROSIS SCORING SYSTEMS USING HIGH-RESOLUTION COMPUTED TOMOGRAPHY BRODY SCORING AS REFERENCE

Rossi-Norrlund, Rauni, 1962 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
Meltzer, Carin (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
Söderman, Christina (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för medicinsk strålningsvetenskap,Institute of Clinical Sciences, Department of Medical Radiation Sciences
visa fler...
Johnsson, Åse (Allansdotter), 1966 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
Vikgren, Jenny, 1957 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
Molnar, David (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
Gilljam, Marita, 1956 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin,Institute of Medicine
Båth, Magnus, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för medicinsk strålningsvetenskap,Institute of Clinical Sciences, Department of Medical Radiation Sciences
visa färre...
 (creator_code:org_t)
2021-05-05
2021
Engelska.
Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 195:3-4, s. 443-453
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To evaluate two chest tomosynthesis (CTS) scoring systems for cystic fibrosis (CF), one system developed by Vult von Steyern et al. (VvS) and one system based on the Brody scoring system for high-resolution computed tomography (HRCT) (modified Brody (mB)). Brody scoring of HRCT was used as reference. Methods: In conjunction with routine control HRCT at clinical follow-up, 10 consecutive adult CF patients underwent CTS for research purposes. Four radiologists scored the CTS examinations using the mB and VvS scoring systems. All scores were compared to the Brody HRCT scores. The agreement between the evaluated CTS scoring systems and the reference HRCT scoring system was determined using Spearman's rank correlation coefficient and the intraclass correlation coefficient (ICC). Major findings: Spearman's rank correlation coefficient showed strong correlations between HRCT score and both the mB and the VvS CTS total scores (median r(s) = 0.81 and 0.85, respectively). The ICC showed strong correlation between the CTS scoring systems and the reference: 0.88 for mB and 0.85 for VvS scoring. The median time for scoring was 20 and 10 minutes for the mB and VvS scoring systems, respectively. Conclusions: Both evaluated CTS scoring systems correlate well with the reference standard Brody HRCT scoring. The VvS CTS scoring system has a shorter reading time, suggesting its advantage in clinical practice.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

children
observer
software
viewdex
damage
tool
Environmental Sciences & Ecology
Public
Environmental & Occupational
Health
Nuclear Science & Technology
Radiology
Medical Imaging

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy