SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/310267"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/310267" > Urdu translation an...

Urdu translation and cross-cultural validation of the Fugl-Meyer assessment in people with stroke

Ikram, M. (författare)
Rehman, S. S. U. (författare)
Stibrant Sunnerhagen, Katharina, 1957 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för klinisk neurovetenskap,Institute of Neuroscience and Physiology, Department of Clinical Neuroscience
visa fler...
Alt Murphy, Margit, 1970 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för klinisk neurovetenskap,Institute of Neuroscience and Physiology, Department of Clinical Neuroscience
visa färre...
 (creator_code:org_t)
2021-11-22
2022
Engelska.
Ingår i: Disability and Rehabilitation. - : Informa UK Limited. - 0963-8288 .- 1464-5165. ; 44:25, s. 8048-8053
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose The purpose of this study was to translate the FMA for Upper and Lower Extremity into Urdu and determine the validity and reliability of the translated Urdu FMA in people with chronic stroke. Materials and methods A Standardized step-wise forward-backward translation of FMA into Urdu was conducted with the help of bilingual translators, experts from Riphah International University, and experts familiar with the original FMA scale to ensure conceptual equivalency. The final version was constructed after pilot testing of the Urdu FMA on 10 stroke patients. Inter- and intra-rater reliability, content, concurrent and construct validity were determined in 50 individuals with chronic stroke (mean age 53.2 years). Results Intra- and inter-rater reliability, determined by Weighted kappa was satisfactory (k = 0.75-0.99). Internal consistency determined by Cronbach alpha was above 0.80. The content validity Index was acceptable (0.92). Moderate correlations were found with Functional Independence Measure, Modified Rankin Scale, and National Institute of Health Stroke Severity (r = 0.69-0.79). The factor analysis showed that two factors (upper and lower extremity) explained 67.8% of the variance. Conclusion The Urdu FMA is reliable and valid for the assessment of sensorimotor function in people with chronic stroke and can therefore be recommended for use in clinical and research applications.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Neurovetenskaper (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Neurosciences (hsv//eng)

Nyckelord

FMA
validity
reliability
stroke
motor assessment
upper extremity
lower extremity
outcome measures
motor recovery
reliability
validity
scale
Rehabilitation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ikram, M.
Rehman, S. S. U.
Stibrant Sunnerh ...
Alt Murphy, Marg ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinska och f ...
och Neurovetenskaper
Artiklar i publikationen
Disability and R ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy