SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/312509"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/312509" > Achieving stomal co...

Achieving stomal continence with an ileal pouch and a percutaneous implant.

Johansson, Martin L (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Hultén, Leif (författare)
Jonsson, Olof, 1941 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för urologi,Institute of Clinical Sciences, Department of Urology
visa fler...
Ben Amara, Heithem, 1984 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Thomsen, Peter, 1953 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Edwin, Bjørn (författare)
visa färre...
 (creator_code:org_t)
2022-01-04
2022
Engelska.
Ingår i: Journal of materials science. Materials in medicine. - : Springer Science and Business Media LLC. - 1573-4838 .- 0957-4530. ; 33:1
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this study, a soft-tissue-anchored, percutaneous port used as a mechanical continence-preserving valve in reservoir ileo- and urostomies was functionally and morphologically evaluated in eight dogs. During follow-up, the skin failed to attach to the implant, but the intestine inside the stoma port appeared to be attached to the mesh. After reaching adequate reservoir volume, the urostomies were rendered continent by attaching a lid to the implant. The experiments were ended at different time intervals due to implant-related adverse events. In only one case did the histological evaluation reveal integration at both the implant-intestine and implant-skin interfaces, with a low degree of inflammation and the absence of bacterial colonisation. In the remaining cases, integration was not obtained and instead mucosal downgrowth and biofilm formation were observed. The skin-implant junction was characterised by the absence of direct contact between the epidermis and the implant. Varying degrees of epidermal downgrowth, granulation tissue formation, inflammatory cell infiltration and bacterial growth and biofilm formation were prominent findings. In contrast, the subcutaneously located anchor part of the titanium port was well integrated and encapsulated by fibrous tissue. These results demonstrate the opportunity to achieve integration between a soft-tissue-anchored titanium port, skin and intestine. However, predictable long-term function could not be achieved in these animal models due to implant- and non-implant-related adverse events. Unless barriers at both the implant-skin and implant-intestine junctions are created, epidermal and mucosal downward migration and biofilm formation will jeopardise implant performance.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomaterialvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomaterials Science (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy