SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/319000"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/319000" > Absolute and relati...

Absolute and relative intrarater reliability of the modified motor assessment scale according to Uppsala academic hospital-99

Vive, Sara (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för hälsa och rehabilitering,Institute of Neuroscience and Physiology, Department of Health and Rehabilitation
Bunketorp Käll, Lina, 1975 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för hälsa och rehabilitering,Institute of Neuroscience and Physiology, Department of Health and Rehabilitation
 (creator_code:org_t)
2022-09-15
2024
Engelska.
Ingår i: Physiotherapy Theory and Practice. - : Informa UK Limited. - 0959-3985 .- 1532-5040. ; 40:3, s. 594-602
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background For some of the most commonly used motor measures, psychometric properties, and minimal detectable change (MDC95) remain largely unknown, limiting the interpretability of tests. Objective The aim was to establish intrarater reliability, MDC95 and floor- and ceiling effects for a modified version of the Motor Assessment Scale (M-MAS UAS-99). Methods Data was derived from an intervention study that enrolled 41 individuals with chronic stroke. Test scores from two subsequent assessments with 3 weeks apart were used for establishing the floor and ceiling effect, the intraclass correlation coefficient (ICC[2,1]), standard error mean (SEM) and the MDC95 for the total score, and subdomains of the M-MAS UAS-99. Results The intrarater reliability was excellent with an ICC[2,1] between 0.970 and 0.995 for both total score and subdomains. The MDC95 for the M-MAS UAS-99 total score was 1.22 which means >= 2.0 points on an individual basis. For bed mobility subdomain, a ceiling effect was seen, but not for the total score of the test. No floor effect was seen for the test. Conclusion M-MAS UAS-99 has excellent intrarater reliability. Any individual increase in test scores must reach 2.0 to be considered a true change.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences (hsv//eng)

Nyckelord

Chronic stroke
reliability
minimal detectable change
functional motor
ability
berg balance scale
induced movement therapy
standardized approach
detectable change
stroke
reproducibility
responsiveness
validity
mobility
anchor
Rehabilitation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Vive, Sara
Bunketorp Käll, ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
Artiklar i publikationen
Physiotherapy Th ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy