Microwave Antenna System for Muscle Rupture Imaging with a Lossy Gel to Reduce Multipath Interference
-
- Guerrero Orozco, Laura, 1996 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology,Sahlgrenska universitetssjukhuset,Sahlgrenska University Hospital
-
- Peterson, Lars, 1936 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences,University of Gothenburg
-
- Fhager, Andreas, 1976 (författare)
- Sahlgrenska universitetssjukhuset,Sahlgrenska University Hospital,Chalmers tekniska högskola,Chalmers University of Technology
-
(creator_code:org_t)
- 2022-05-29
- 2022
- Engelska.
-
Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 22:11
- Relaterad länk:
-
https://research.cha... (primary) (free)
-
visa fler...
-
https://gup.ub.gu.se...
-
https://doi.org/10.3...
-
https://research.cha...
-
visa färre...
Abstract
Ämnesord
Stäng
- Injuries to the hamstring muscles are an increasing problem in sports. Imaging plays a key role in diagnosing and managing athletes with muscle injuries, but there are several problems with conventional imaging modalities with respect to cost and availability. We hypothesized that microwave imaging could provide improved availability and lower costs and lead to improved and more accurate diagnostics. In this paper, a semicircular microwave imaging array with eight antennae was investigated. A key component in this system is the novel antenna design, which is based on a monopole antenna and a lossy gel. The purpose of the gel is to reduce the effects of multipath signals and improve the imaging quality. Several different gels have been manufactured and evaluated in imaging experiments. For comparison, corresponding simulations were performed. The results showed that the gels can effectively reduce the multipath signals and the imaging experiments resulted in significantly more stable and repeatable reconstructions when a lossy gel was used compared to when an almost non-lossy gel was used.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinsk bioteknologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Medical Biotechnology (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Annan medicinteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Other Medical Engineering (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Elektroteknik och elektronik -- Signalbehandling (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Electrical Engineering, Electronic Engineering, Information Engineering -- Signal Processing (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- microwave imaging
- medical diagnosis
- antenna system
- muscle rupture
- prototype
- multipath signal
- image reconstruction
- breast-cancer detection
- hamstring injuries
- diagnosis
- reconstruction
- phantoms
- strains
- Chemistry
- Engineering
- Instruments & Instrumentation
- prototype
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
-
Sensors
(Sök värdpublikationen i LIBRIS)
Till lärosätets databas