Preanalytical stability of plasma biomarkers for Alzheimer's disease pathology

Sunde, A. L. (författare)
Alsnes, I. V. (författare)
Aarsland, D. (författare)
Karolinska Institutet
visa fler...
Ashton, Nicholas J. (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för psykiatri och neurokemi,Institute of Neuroscience and Physiology, Department of Psychiatry and Neurochemistry
Tovar-Rios, D. A. (författare)
de Santis, Giovanni, 1993 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för psykiatri och neurokemi,Institute of Neuroscience and Physiology, Department of Psychiatry and Neurochemistry
Blennow, Kaj, 1958 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för psykiatri och neurokemi,Institute of Neuroscience and Physiology, Department of Psychiatry and Neurochemistry
Zetterberg, Henrik, 1973 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för psykiatri och neurokemi,Institute of Neuroscience and Physiology, Department of Psychiatry and Neurochemistry
Kjosavik, S. R. (författare)
visa färre...
 (creator_code:org_t)
2023
2023
Engelska.
Ingår i: Alzheimer's and Dementia: Diagnosis, Assessment and Disease Monitoring. - 2352-8729. ; 15:2
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • IntroductionPlasma tests have demonstrated high diagnostic accuracy for identifying Alzheimer's disease pathology. To facilitate the transition to clinical utility, we assessed whether plasma storage duration and temperature affect the biomarker concentrations. MethodsPlasma samples from 13 participants were stored at +4 degrees C and +18 degrees C. Concentrations of six biomarkers were measured after 2, 4, 6, 8, 10, and 24 h by single molecule array assays. ResultsPhosphorylated tau 181 (p-tau181), phosphorylated tau 231 (p-tau231), neurofilament light (NfL), and glial fibrillary acidic protein (GFAP) concentrations were unchanged both when stored at +4 degrees C and +18 degrees C. Amyloid-beta 40 (A beta 40) and amyloid-beta 42 (A beta 42) concentrations were stable for 24 h at +4 degrees C but declined when stored at +18 degrees C for longer than 6 h. This decline did not affect the A beta 42/A beta 40 ratio. DiscussionPlasma samples can be stored for 24 h at +4 degrees C or +18 degrees C and result in valid assay results for p-tau181, p-tau231, A beta 42/A beta 40 ratio, GFAP, and NfL. HIGHLIGHTSPlasma samples were stored for 24 h at +4 degrees C and +18 degrees C, mimicking clinical practice.Concentrations for Alzheimer's disease biomarkers were measured at six time-points.p-tau181, p-tau231, NfL, and GFAP concentrations were unchanged during the experiment.Storage at +18 degrees C affected A beta 40 and A beta 42 concentrations while storage at +4 degrees C did not. The A beta 42/A beta 40 ratio was unaffected.These plasma tests seem suitable for use in general practice.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Neurovetenskaper (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Neurosciences (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Geriatrik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Geriatrics (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Klinisk laboratoriemedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Clinical Laboratory Medicine (hsv//eng)

Nyckelord

Alzheimer disease
amyloid beta
biomarker
glial fibrillary acidic
protein
neurofilament protein light
phosphorylated tau
plasma
pre-analytics

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy