Sökning: id:"swepub:oai:gup.ub.gu.se/328338" >
Ultra-Low Dose of S...
Ultra-Low Dose of Superparamagnetic Iron Oxide Nanoparticles for Sentinel Lymph Node Detection in Patients with Breast Cancer
-
- Mirzaei, Nushin (författare)
- Gothenburg University,Göteborgs universitet,Sahlgrenska Centrum för Cancerforskning (SCCR),Wallenberg Centre for Molecular and Translational Medicine,Sahlgrenska Center for Cancer Research (SCCR)
-
- Wärnberg, Fredrik (författare)
- Gothenburg University,Göteborgs universitet,Sahlgrenska Centrum för Cancerforskning (SCCR),Sahlgrenska Center for Cancer Research (SCCR)
-
- Zaar, Pontus (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
-
visa fler...
-
- Leonhardt, Henrik, 1963 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
-
- Olofsson Bagge, Roger, 1978 (författare)
- Gothenburg University,Göteborgs universitet,Sahlgrenska Centrum för Cancerforskning (SCCR),Wallenberg Centre for Molecular and Translational Medicine,Sahlgrenska Center for Cancer Research (SCCR)
-
visa färre...
-
(creator_code:org_t)
- 2023
- 2023
- Engelska.
-
Ingår i: Annals of Surgical Oncology. - 1068-9265. ; 30, s. 5685-5689
- Relaterad länk:
-
https://gup.ub.gu.se...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- BackgroundSentinel lymph node (SLN) status is pivotal for treatment decision-making in patients with breast cancer. Superparamagnetic iron oxide nanoparticles (SPIO) have been shown to be equivalent to the dual technique with technetium(99m) (Tc-99) and blue dye (BD) for SLN detection. The aim of this study was to determine the feasibility of detecting SLNs using an ultra-low dose of SPIO.MethodPatients planned for breast conserving surgery and SLN biopsy were included. An intradermal injection of 0.1 mL SPIO was administered at the areolar border up to 7 days before surgery. Tc-99/BD was administered according to clinical routine. SLNs were detected during surgery using a handheld magnetometer. All nodes with a magnetic and/or radioactive signal, as well as blue or clinically suspicious nodes, were harvested and analyzed.ResultsIn 50 patients, SPIO was injected a median of 4 days before surgery. At least one SLN was found in all patients with both methods. A total of 98 SLNs were removed; 90 were detected using SPIO and 88 using Tc-99/BD. Of the 90 SLNs detected by SPIO, 80 were Tc-99/BD positive (concordance 89%). Histopathological analysis classified 16 patients with tumor cells deposit and 9 with macro-metastasis > 2mm, where one SLN was identified only by the radioactive technique and one only by the magnetic technique.DiscussionSLN detection using 0.1 mL ultra-low dose SPIO injected intradermally was successful in all patients. A future analysis will determine whether the approach using an ultra-low dose of SPIO injected intradermally will minimize skin staining and MRI artefacts.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cancer and Oncology (hsv//eng)
Nyckelord
- Breast cancer
- Sentinel lymph node biopsy
- Superparamagnetic iron oxide nanoparticles
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas