SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/330667"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/330667" > Visualization of th...

Visualization of the distortion induced by nonlinear noise reduction in computed tomography

Larsson, Joel, 1986 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Båth, Magnus, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Thilander-Klang, Anne, 1959 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
 (creator_code:org_t)
2023
2023
Engelska.
Ingår i: Journal of Medical Imaging. - 2329-4302. ; 10:3
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: We developed a method to visualize the image distortion induced by nonlinear noise reduction algorithms in computed tomography (CT) systems.Approach: Nonlinear distortion was defined as the induced residual when testing a reconstruction algorithm by the criteria for a linear system. Two types of images were developed: a nonlinear distortion of an object (NLDobject) image and a nonlinear distortion of noise (NLDnoise) image to visualize the nonlinear distortion induced by an algorithm. Calculation of the images requires access to the sinogram data, which is seldomly fully provided. Hence, an approximation of the NLDobject image was estimated. Using simulated CT acquisitions, four noise levels were added onto forward projected sinograms of a typical CT image; these were noise reduced using a median filter with the simultaneous iterative reconstruction technique or a total variation filter with the conjugate gradient least-squares algorithm. The linear reconstruction technique filtered back-projection was also analyzed for comparison.Results: Structures in the NLDobject image indicated contrast and resolution reduction of the nonlinear denoising. Although the approximated NLDobject image represented the original NLDobject image well, it had a higher random uncertainty. The NLDnoise image for the median filter indicated both stochastic variations and structures reminding of the object while for the total variation filter only stochastic variations were indicated.Conclusions: The developed images visualize nonlinear distortions of denoising algorithms. The object may be distorted by the noise and vice versa. Analyzing the distortion correlated to the object is more critical than analyzing a distortion of stochastic variations. The absence of nonlinear distortion may measure the robustness of the denoising algorithm.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

computed tomography
image quality
noise reduction algorithms
nonlinear reconstruction
radiation-dose reduction
iterative reconstruction
ct
performance
algorithm
detectability
contrast
Radiology
Nuclear Medicine & Medical Imaging

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Larsson, Joel, 1 ...
Båth, Magnus, 19 ...
Thilander-Klang, ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Journal of Medic ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy