Differences and agreement between two portable hand-held spirometers across diverse community-based populations in the Prospective Urban Rural Epidemiology (PURE) study.

Duong, MyLinh (författare)
Rangarajan, Sumathy (författare)
Zaman, Michele (författare)
visa fler...
Nasir, Nafiza Mat (författare)
Seron, Pamela (författare)
Yeates, Karen (författare)
Yusufali, Afzalhussein M (författare)
Khatib, Rasha (författare)
Tse, Lap Ah (författare)
Wang, Chuangshi (författare)
Wielgosz, Andreas (författare)
Teo, Koon (författare)
Kumar, Rajesh (författare)
Avezum, Alvaro (författare)
Ismail, Rosnah (författare)
Çalık, Burcu Tumerdem (författare)
Gopakumar, Soumya (författare)
Rahman, Omar (författare)
Zatońska, Katarzyna (författare)
Rosengren, Annika, 1951 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
Otero, Johanna (författare)
Kelishadi, Roya (författare)
Diaz, Rafael (författare)
Puoane, Thandi (författare)
Yusuf, Salim (författare)
visa färre...
 (creator_code:org_t)
2022-02-02
2022
Engelska.
Ingår i: PLOS global public health. - : Public Library of Science (PLoS). - 2767-3375. ; 2:2
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Portable spirometers are commonly used in longitudinal epidemiological studies to measure and track the forced expiratory volume in first second (FEV1) and forced vital capacity (FVC). During the course of the study, it may be necessary to replace spirometers with a different model. This raise questions regarding the comparability of measurements from different devices. We examined the correlation, mean differences and agreement between two different spirometers, across diverse populations and different participant characteristics.From June 2015 to Jan 2018, a total of 4,603 adults were enrolled from 628 communities in 18 countries and 7 regions of the world. Each participant performed concurrent measurements from the MicroGP and EasyOne spirometer. Measurements were compared by the intra-class correlation coefficient (ICC) and Bland-Altman method.Approximately 65% of the participants achieved clinically acceptable quality measurements. Overall correlations between paired FEV1 (ICC 0.88 [95% CI 0.87, 0.88]) and FVC (ICC 0.84 [0.83, 0.85]) were high. Mean differences between paired FEV1 (-0.038 L [-0.053, -0.023]) and FVC (0.033 L [0.012, 0.054]) were small. The 95% limits of agreement were wide but unbiased (FEV1 984, -1060; FVC 1460, -1394). Similar findings were observed across regions. The source of variation between spirometers was mainly at the participant level. Older age, higher body mass index, tobacco smoking and known COPD/asthma did not adversely impact on the inter-device variability. Furthermore, there were small and acceptable mean differences between paired FEV1 and FVC z-scores using the Global Lung Initiative normative values, suggesting minimal impact on lung function interpretation.In this multicenter, diverse community-based cohort study, measurements from two portable spirometers provided good correlation, small and unbiased differences between measurements. These data support their interchangeable use across diverse populations to provide accurate trends in serial lung function measurements in epidemiological studies.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy