SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/338458"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/338458" > Changes in temperat...

Changes in temperature in preheated crystalloids at ambient temperatures relevant to a prehospital setting: an experimental simulation study with the application of prehospital treatment of trauma patients suffering from accidental hypothermia

Jensen, Emil (författare)
Högskolan i Borås
Rentzhog, Helena (författare)
Högskolan i Borås
Herlitz, Johan, 1949- (författare)
Högskolan i Borås,Akademin för vård, arbetsliv och välfärd
visa fler...
Axelsson, Christer (författare)
Högskolan i Borås,Akademin för vård, arbetsliv och välfärd
Lundgren, Peter (författare)
Högskolan i Borås,Gothenburg University,Göteborgs universitet,Institutionen för medicin,Institute of Medicine,Akademin för vård, arbetsliv och välfärd
visa färre...
 (creator_code:org_t)
BioMed Central (BMC), 2024
2024
Engelska.
Ingår i: BMC EMERGENCY MEDICINE. - : BioMed Central (BMC). - 1471-227X. ; 24:1
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background Accidental hypothermia is common in all trauma patients and contributes to the lethal diamond, increasing both morbidity and mortality. In hypotensive shock, fluid resuscitation is recommended using fluids with a temperature of 37-42 degrees, as fluid temperature can decrease the patient's body temperature. In Sweden, virtually all prehospital services use preheated fluids. The aim of the present study was to investigate how the temperature of preheated infusion fluids is affected by the ambient temperatures and flow rates relevant for prehospital emergency care.Methods In this experimental simulation study, temperature changes in crystalloids preheated to 39 degrees C were evaluated. The fluid temperature changes were measured both in the infusion bag and at the patient end of the infusion system. Measurements were conducted in conditions relevant to prehospital emergency care, with ambient temperatures varying between - 4 and 28 degrees C and flow rates of 1000 ml/h and 6000 ml/h, through an uninsulated infusion set at a length of 175 cm.Results The flow rate and ambient temperature affected the temperature in the infusion fluid both in the infusion bag and at the patient end of the system. A lower ambient temperature and lower flow rate were both associated with a greater temperature loss in the infusion fluid.Conclusion This study shows that both a high infusion rate and a high ambient temperature are needed if an infusion fluid preheated to 39 degrees C is to remain above 37 degrees C when it reaches the patient using a 175-cm-long uninsulated infusion set. It is apparent that the lower the ambient temperature, the higher the flow rate needs to be to limit temperature loss of the fluid.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Omvårdnad (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Nursing (hsv//eng)

Nyckelord

Accidental hypothermia
Advanced trauma life support care
Resuscitation
Människan i vården

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy