Sökning: id:"swepub:oai:gup.ub.gu.se/52324" >
Vectorcardiographic...
Vectorcardiographic ST deviations related to increased heart rate in the absence of ischemia in an experimental pig model.
-
- Häggmark, Sören (författare)
- Umeå universitet,Anestesiologi och intensivvård
-
- Haney, Michael F (författare)
- Umeå universitet,Anestesiologi och intensivvård
-
- Johansson, Göran (författare)
- Umeå universitet,Anestesiologi och intensivvård
-
visa fler...
-
- Biber, Björn, 1944 (författare)
- Umeå universitet,Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för anestesiologi och intensivvård,Institute of Clinical Sciences, Department of Anesthesiology and Intensive care,Anestesiologi och intensivvård
-
- Näslund, Ulf (författare)
- Umeå universitet,Institutionen för folkhälsa och klinisk medicin,Kardiologi
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2006
- 2006
- Engelska.
-
Ingår i: J Electrocardiol. - : Elsevier BV. - 0022-0736 .- 1532-8430. ; 39:2, s. 169-76
- Relaterad länk:
-
http://umu.diva-port...
-
visa fler...
-
http://www.ncbi.nlm....
-
https://umu.diva-por... (primary) (Raw object)
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- The electrocardiographic ST segment may change when heart rate (HR) increases. We aimed to analyze vectorcardiographic ST relation and myocardial conditions during controlled HR increases in anesthetized pigs. The relative parameters ST change vector magnitude and ST change vector angle were calculated at paced HRs ranging from 85 to 175 beats per minute. ST change vector magnitude increased from baseline 6.3 +/- 1.3 to 26.0 +/- 3.1 microV (P < .01; range, 4-50 microV) at HR 175 beats per minute with similar changes in ST change vector angle, whereas the absolute parameter ST vector magnitude demonstrated a heterogeneous pattern without any systematic relation to HR changes. Microdialysis results from left ventricular wall, with analysis of glucose, lactate, and pyruvate, showed no sign of ischemia during pacing. Potassium concentrations did not change during pacing. We conclude that significant HR-related ST vector changes can occur in the absence of myocardial ischemia.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)
Nyckelord
- Animals
- Cardiac Pacing
- Artificial
- Female
- Heart Rate
- physiology
- Myocardial Ischemia
- physiopathology
- Swine
- Tachycardia
- physiopathology
- Vectorcardiography
- Animals
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas