SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/56127"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/56127" > A novel particle tr...

A novel particle trap impactor for use with the gas-quenching probe sampling system

Tran, K. Q. (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kemi,Department of Chemistry,University of Gothenburg
Hagström, Magnus, 1965 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kemi,Department of Chemistry,University of Gothenburg
Korsgren, John G. (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kemi,Department of Chemistry,University of Gothenburg
visa fler...
Steenari, Britt-Marie, 1953 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Lindqvist, Oliver, 1943 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kemi,Department of Chemistry,University of Gothenburg
Pettersson, Jan B. C., 1962 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kemi,Department of Chemistry,University of Gothenburg
visa färre...
 (creator_code:org_t)
Informa UK Limited, 2004
2004
Engelska.
Ingår i: Aerosol Science and Technology. - : Informa UK Limited. - 0278-6826 .- 1521-7388. ; 38:10, s. 955-962
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A novel particle trap impactor has been developed for use with the gas-quenching probe in order to exclude solid particles from entering into the probe during sampling of gaseous metallic species in fluidized bed combustion conditions. The impactor must be small in size (empty set(impactor)less than or equal toempty set(probe) = 45 mm) but capable of collecting a relatively large amount of particles at elevated temperatures. As the first step, the impactor was designed, constructed, and tested at room temperature for KCl aerosol particles. The impactor with a nozzle of 0.95 mm in diameter, in combination with the orifice-to-jet diameter ratio of 1.5 and the ratio of the jet-to-plate spacing to jet diameter at 1.4 yielded a sharp cutoff curve with a maximum collection efficiency of about 0.9 and a rootStk(50) value of about 0.22. In addition, the collection efficiency of the impactor was compared with the particle removal efficiency of a filter of the same type as the filter previously used with the gas-quenching probe. The difference from the comparison is very small, indicating that the impactor can be used to replace the filter to prevent fly ash particles from entering the gas-quenching probe in fluidized bed combustion conditions.

Ämnesord

NATURVETENSKAP  -- Kemi -- Fysikalisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Physical Chemistry (hsv//eng)

Nyckelord

FLUIDIZED-BED BOILER
SIZE DISTRIBUTIONS
COMBUSTION-CHAMBER
VIRTUAL
IMPACTOR
HIGH-TEMPERATURE
HIGH-PRESSURE
AEROSOLS
CONDENSATION
PERFORMANCE
AMMONIA
HIGH-PRESSURE

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy