SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/56401"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/56401" > Variation in surfac...

Variation in surface texture measurements.

Macdonald, Warren, 1954 (författare)
Campbell, Patricia (författare)
Fisher, John (författare)
visa fler...
Wennerberg, Ann, 1955 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för biomaterialvetenskap,Institute of Surgical Sciences, Department of Biomaterials
visa färre...
 (creator_code:org_t)
2004
2004
Engelska.
Ingår i: Journal of biomedical materials research. Part B, Applied biomaterials. - : Wiley. - 1552-4973. ; 70:2, s. 262-9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Surface texture influences cellular response to implants, implant wear, and fixation, yet measurement and reporting of surface texture can be confusing and ambiguous. Seven specimens of widely different surface textures were submitted to three internationally renowned laboratories for surface texture characterization. The specimens were from dental implants, orthopedic implants, and femoral heads. Areas to be measured were clearly marked; simplified instructions were supplied but specific measurement parameters were not requested. Techniques used included contact profilometry, two- and three-dimensional laser profilometry, and atomic force microscopy. Four to thirteen parameters were reported, 2D or 3D, including R(a) or S(a); only three were common to all centers. The results varied by as much as +/-300-1000%, depending on technique and surface type. Some surfaces were not measurable by some techniques. One dental implant surface was reported with R(a) of 0.17, 0.85, 1.9, and 4.4 microm. The CoCr femoral head ranged from an R(a) of 0.011 to 0.10 microm; the zirconia head from 0.006 to 0.05 microm. Similar variability was reported for the other parameters. Useful surface texture characterization requires reporting of all measurement parameters. Comparisons between studies may be compromised if differences in technique are not considered.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

Dental Implants
Laboratories
standards
Microscopy
Atomic Force
Microscopy
Confocal
Prostheses and Implants
Surface Properties

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy