SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/57208"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/57208" > Three-year folow-up...

Three-year folow-up of posterior capsule opacification with two different silicone intraocular lenses.

Sundelin, Karin (författare)
Gothenburg University,Göteborgs universitet,Institutionen för klinisk neurovetenskap, Sektionen för oftalmologi,Institute of Clinical Neurosciences, Section of Ophtalmology
Shams, H (författare)
Stenevi, Ulf, 1943 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för klinisk neurovetenskap, Sektionen för oftalmologi,Institute of Clinical Neurosciences, Section of Ophtalmology
 (creator_code:org_t)
2005
2005
Engelska.
Ingår i: Acta Ophthalmologica Scandinavica. - 1395-3907. ; 83, s. 11-19
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • ABSTRACT. Purpose: To compare posterior capsule opacification (PCO) after cataract surgery with implantation of two silicone intraocular lenses (IOLs) with different designs. Methods: We carried out a prospective, clinical study of 116 patients randomized to standardized phacoemulsification with implantation of CeeOn Edge (n = 57) or SI40NB (n = 59) IOLs. The follow-up period was 3 years. To evaluate PCO morphologically, digital images were obtained and analysed using evaluation of posterior capsule opacification computer software (EPCO). The neodymium: YAG (Nd:YAG) capsulotomy rate was recorded. Results: At 2 and 3 years, the eyes with SI40NB IOLs had significantly more PCO than those with the CeeOn Edge IOLs (p = 0.00014 and p = 0.002). Nine Nd:YAG capsulotomies were performed in the SI40NB group and none in the CeeOn Edge group. This difference was statistically significant (p = 0.003). In some patients a regression of PCO was noticed and confirmed using EPCO. Statistically less PCO was noted when the capsulorhexis rim was placed so that it covered all 360 degrees of the optic of the IOL. Conclusions: A clinically and statistically significant difference in PCO development between CeeOn Edge and SI40NB IOLs at 2 and 3 years postoperatively was found. These findings support earlier studies indicating that a sharp edge of the optic is a more important factor in IOL design than IOL material in the prevention of PCO. Key words: posterior capsule opacification (PCO) – silicone – intraocular lens (IOL) – longterm follow-up – prospective – evaluation of posterior capsule opacification (EPCO) – capsulotomy – optic edge – regression

Nyckelord

posterior capsule opacification (PCO) – silicone – intraocular lens (IOL) – longterm

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Sundelin, Karin
Shams, H
Stenevi, Ulf, 19 ...
Artiklar i publikationen
Acta Ophthalmolo ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy