Accurate and sensitive measurements of magnetic susceptibility using echo planar imaging.

Carlsson, Åsa, 1978 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för fysik (GU),Department of Physics (GU)
Starck, Göran (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Ljungberg, Maria (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
visa fler...
Ekholm, Sven (författare)
Forssell-Aronsson, Eva, 1961 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
visa färre...
 (creator_code:org_t)
Elsevier BV, 2006
2006
Engelska.
Ingår i: Magnetic resonance imaging. - : Elsevier BV. - 0730-725X. ; 24:9, s. 1179-85
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Susceptibility differences are common causes for artifacts in magnetic resonance (MR); therefore, it is important to choose phantom materials in a way that these artifacts are kept at a minimum. In this study, a previously proposed MR imaging (MRI) method [Beuf O, Briguet A, Lissac M, Davis R. Magnetic resonance imaging for the determination of magnetic susceptibility of materials. J Magn Reson 1996; Series B(112):111-118] was improved to facilitate sensitive in-house measurements of different phantom materials so that such artifacts can more easily be minimized. Using standard MRI protocols and distilled water as reference, we measured magnetic volume susceptibility differences with a clinical MR system. Two imaging techniques, echo planar imaging (EPI) and spin echo, were compared using liquid samples whose susceptibilities were verified by MR spectroscopy. The EPI sequence has a very narrow bandwidth in the phase-encoding direction, which gives an increased sensitivity to magnetic field inhomogeneities. All MRI measurements were evaluated in two ways: (1) manual image analysis and (2) model fitting. The narrow bandwidth of the EPI made it possible to detect very small susceptibility differences (equivalent susceptibility difference, Deltachi(e)> or =0.02 ppm), and even plastics could be measured. Model fitting yielded high accuracy and high sensitivity and was less sensitive to other image artifacts as compared with manual image analysis.

Nyckelord

Artifacts
Echo-Planar Imaging
instrumentation
Magnetic Resonance Spectroscopy
instrumentation
Phantoms
Imaging
Sensitivity and Specificity

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy