SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/60285"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/60285" > A new automated met...

A new automated method for analysis of gated-SPECT images based on a three-dimensional heart shaped model

Lomsky, Milan, 1948 (författare)
Gothenburg University,Göteborgs universitet,Hjärt-kärlinstitutionen,Cardiovascular Institute
Richter, J. (författare)
Johansson, L. (författare)
visa fler...
El Ali, Henrik Hussein (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Åström, Karl (författare)
Lund University,Lunds universitet,Matematik LTH,Matematikcentrum,Institutioner vid LTH,Lunds Tekniska Högskola,Mathematics (Faculty of Engineering),Centre for Mathematical Sciences,Departments at LTH,Faculty of Engineering, LTH
Ljungberg, Michael (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Edenbrandt, Lars, 1957 (författare)
Lund University,Lunds universitet,Gothenburg University,Göteborgs universitet,Hjärt-kärlinstitutionen,Cardiovascular Institute,Nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Nuclear medicine, Malmö,Lund University Research Groups
visa färre...
 (creator_code:org_t)
2005
2005
Engelska.
Ingår i: Clin Physiol Funct Imaging. - 1475-0961. ; 25:4, s. 234-40
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A new automated method for quantification of left ventricular function from gated-single photon emission computed tomography (SPECT) images has been developed. The method for quantification of cardiac function (CAFU) is based on a heart shaped model and the active shape algorithm. The model contains statistical information of the variability of left ventricular shape. CAFU was adjusted based on the results from the analysis of five simulated gated-SPECT studies with well defined volumes of the left ventricle. The digital phantom NURBS-based Cardiac-Torso (NCAT) and the Monte-Carlo method SIMIND were used to simulate the studies. Finally CAFU was validated on ten rest studies from patients referred for routine stress/rest myocardial perfusion scintigraphy and compared with Cedar-Sinai quantitative gated-SPECT (QGS), a commercially available program for quantification of gated-SPECT images. The maximal differences between the CAFU estimations and the true left ventricular volumes of the digital phantoms were 11 ml for the end-diastolic volume (EDV), 3 ml for the end-systolic volume (ESV) and 3% for the ejection fraction (EF). The largest differences were seen in the smallest heart. In the patient group the EDV calculated using QGS and CAFU showed good agreement for large hearts and higher CAFU values compared with QGS for the smaller hearts. In the larger hearts, ESV was much larger for QGS than for CAFU both in the phantom and patient studies. In the smallest hearts there was good agreement between QGS and CAFU. The findings of this study indicate that our new automated method for quantification of gated-SPECT images can accurately measure left ventricular volumes and EF.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)

Nyckelord

Artificial Intelligence
Gated Blood-Pool Imaging/instrumentation/*methods
Heart Ventricles/*physiology/*radionuclide imaging
Humans
Image Interpretation
Computer-Assisted/methods
Imaging
Three-Dimensional/*methods
Models
Anatomic
*Models
Cardiovascular
Phantoms
Imaging
Reproducibility of Results
Sensitivity and Specificity
Stroke Volume/*physiology
Tomography
Emission-Computed
Single-Photon/instrumentation/methods
Ventricular Function
Left/*physiology
image processing
computer-assisted diagnosis
gated-SPECT
radionuclide imaging

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy