Sökning: id:"swepub:oai:gup.ub.gu.se/61208" >
Porcine transfer st...
Porcine transfer study: virtual reality simulator training compared with porcine training in endovascular novices
-
- Berry, Max, 1969 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
-
Lystig, T (författare)
-
Beard, J (författare)
-
visa fler...
-
Klingestierna, H (författare)
-
Reznick, R (författare)
-
- Lönn, Lars, 1956 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
-
visa färre...
-
(creator_code:org_t)
- 2007-01-12
- 2007
- Engelska.
-
Ingår i: Cardiovasc Intervent Radiol. - : Springer Science and Business Media LLC. - 0174-1551. ; 30:3, s. 455-61
- Relaterad länk:
-
https://gup.ub.gu.se...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- PURPOSE: To compare the learning of endovascular interventional skills by training on pig models versus virtual reality simulators. METHODS: Twelve endovascular novices participated in a study consisting of a pig laboratory (P-Lab) and a virtual reality laboratory (VR-Lab). Subjects were stratified by experience and randomized into four training groups. Following 1 hr of didactic instruction, all attempted an iliac artery stenosis (IAS) revascularization in both laboratories. Onsite proctors evaluated performances using task-specific checklists and global rating scales, yielding a Total Score. Participants completed two training sessions of 3 hr each, using their group's assigned method (P-Lab x 2, P-Lab + VR-Lab, VR-Lab + P-Lab, or VR-Lab x 2) and were re-evaluated in both laboratories. A panel of two highly experienced interventional radiologists performed assessments from video recordings. ANCOVA analysis of Total Score against years of surgical, interventional radiology (IR) experience and cumulative number of P-Lab or VR-Lab sessions was conducted. Inter-rater reliability (IRR) was determined by comparing proctored scores with the video assessors in only the VR-Lab. RESULTS: VR-Lab sessions improved the VR-Lab Total Score (beta = 3.029, p = 0.0015) and P-Lab Total Score (beta = 1.814, p = 0.0452). P-Lab sessions increased the P-Lab Total Score (beta = 4.074, p < 0.0001) but had no effect on the VR-Lab Total Score. In the general statistical model, both P-Lab sessions (beta = 2.552, p = 0.0010) and VR-Lab sessions (beta = 2.435, p = 0.0032) significantly improved Total Score. Neither previous surgical experience nor IR experience predicted Total Score. VR-Lab scores were consistently higher than the P-Lab scores (Delta = 6.659, p < 0.0001). VR-Lab IRR was substantial (r = 0.649, p < 0.0008). CONCLUSIONS: Endovascular skills learned in the virtual environment may be transferable to the real catheterization laboratory as modeled in the P-Lab.
Nyckelord
- Adult
- Angioplasty
- Balloon/*education
- Animals
- Arterial Occlusive Diseases/*therapy
- Attitude of Health Personnel
- *Computer Simulation
- Curriculum
- *Disease Models
- Animal
- Female
- Humans
- *Iliac Artery
- Male
- Middle Aged
- Radiology
- Interventional/*education
- *Stents
- Swine
- *User-Computer Interface
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas