SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/70804"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/70804" > Validity and reliab...

Validity and reliability of the Muscle Function Scale, aimed to assess the lateral flexors of the neck in infants

Öhman, Anna, 1957 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för arbetsterapi, audiologi och fysioterapi,Institute of Neuroscience and Physiology, Department of Audiology, Logopedics, Occupational Therapy & Physiotherapy,University of Gothenburg
Nilsson, Staffan, 1956 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för matematiska vetenskaper, matematisk statistik,Department of Mathematical Sciences, Mathematical Statistics,Chalmers tekniska högskola,Chalmers University of Technology,University of Gothenburg
Beckung, Eva, 1950 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för arbetsterapi, audiologi och fysioterapi,Institute of Neuroscience and Physiology, Department of Audiology, Logopedics, Occupational Therapy & Physiotherapy,University of Gothenburg
 (creator_code:org_t)
2009-07-10
2009
Engelska.
Ingår i: Physiotherapy Theory and Practice. - : Informa UK Limited. - 0959-3985 .- 1532-5040. ; 25:2, s. 129-137
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Infants with congenital muscular torticollis (CMT) often have an imbalance in muscle function in the lateral flexors of the neck and the need for a valid and reliable assessment tool to determine muscle function in these muscles is essential. The lateral up righting response is used to examine and to strengthen the Sternocleidomastoid muscle. A muscle function scale (MFS) has been refined and used for several years in a clinic for infants with CMT. The MFS describes an infant’s muscle function in the lateral flexors of the neck through ordered categorical scores. The aim of this study was to find out if the Muscle Function Scale (MFS) is valid and reliable. A panel of experts examined validity, Kappa statistic and intraclass correlation coefficient was calculated for inter-rater and intra-rater reliability. Conclusion: The MFS is found to be a valid tool to measure the muscle function of the lateral flexors of the neck in infants with CMT. The inter-rater and intra-rater reliability is high for both novice and experienced physiotherapists (kappa >0.9, ICC >0.9).

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy