Positive end-expiratory pressure optimization using electric impedance tomography in morbidly obese patients during laparoscopic gastric bypass surgery.

Erlandsson, Karin, 1973 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för anestesiologi och intensivvård,Institute of Clinical Sciences, Department of Anesthesiology and Intensive care
Odenstedt, Helena, 1968 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för anestesiologi och intensivvård,Institute of Clinical Sciences, Department of Anesthesiology and Intensive care
Lundin, Stefan, 1953 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för anestesiologi och intensivvård,Institute of Clinical Sciences, Department of Anesthesiology and Intensive care
visa fler...
Stenqvist, Ola, 1944 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för anestesiologi och intensivvård,Institute of Clinical Sciences, Department of Anesthesiology and Intensive care
visa färre...
 (creator_code:org_t)
Wiley, 2006
2006
Engelska.
Ingår i: Acta anaesthesiologica Scandinavica. - : Wiley. - 0001-5172 .- 1399-6576. ; 50:7, s. 833-9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Morbidly obese patients have an increased risk for peri-operative lung complications and develop a decrease in functional residual capacity (FRC). Electric impedance tomography (EIT) can be used for continuous, fast-response measurement of lung volume changes. This method was used to optimize positive end-expiratory pressure (PEEP) to maintain FRC. METHODS: Fifteen patients with a body mass index of 49 +/- 8 kg/m(2) were studied during anaesthesia for laparoscopic gastric bypass surgery. Before induction, 16 electrodes were placed around the thorax to monitor ventilation-induced impedance changes. Calibration of the electric impedance tomograph against lung volume changes was made by increasing the tidal volume in steps of 200 ml. PEEP was titrated stepwise to maintain a horizontal baseline of the EIT curve, corresponding to a stable FRC. Absolute FRC was measured with a nitrogen wash-out/wash-in technique. Cardiac output was measured with an oesophageal Doppler method. Volume expanders, 1 +/- 0.5 l, were given to prevent PEEP-induced haemodynamic impairment. RESULTS: Impedance changes closely followed tidal volume changes (R(2) > 0.95). The optimal PEEP level was 15 +/- 1 cmH(2)O, and FRC at this PEEP level was 1706 +/- 447 ml before and 2210 +/- 540 ml after surgery (P < 0.01). The cardiac index increased significantly from 2.6 +/- 0.5 before to 3.1 +/- 0.8 l/min/m(2) after surgery, and the alveolar dead space decreased. P(a)O2/F(i)O2, shunt and compliance remained unchanged. CONCLUSION: EIT enables rapid assessment of lung volume changes in morbidly obese patients, and optimization of PEEP. High PEEP levels need to be used to maintain a normal FRC and to minimize shunt. Volume loading prevents circulatory depression in spite of a high PEEP level.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)

Nyckelord

Adult
Anesthesia
General
Cardiac Output
Electric Impedance
Female
Functional Residual Capacity
Gastric Bypass
Humans
Laparoscopy
Lung Compliance
Lung Volume Measurements
Male
Middle Aged
Obesity
Morbid
physiopathology
surgery
Positive-Pressure Respiration
methods
Pulmonary Gas Exchange
Tomography

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy