SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/80515"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/80515" > A fully implantable...

A fully implantable multi-channel biotelemetry system for measurement of blood flow and temperature: A first evaluation in the green sturgeon

Gräns, Albin, 1979 (författare)
Gothenburg University,Göteborgs universitet,Zoologiska institutionen,Department of Zoology
Axelsson, Michael, 1958 (författare)
Gothenburg University,Göteborgs universitet,Zoologiska institutionen,Department of Zoology
Pitsillides, K. (författare)
visa fler...
Olsson, Catharina, 1968 (författare)
Gothenburg University,Göteborgs universitet,Zoologiska institutionen,Department of Zoology
Höjesjö, Johan, 1967 (författare)
Gothenburg University,Göteborgs universitet,Zoologiska institutionen,Department of Zoology
Kaufmann, R.C. (författare)
Cech, J.J. Jr (författare)
visa färre...
 (creator_code:org_t)
2008-09-11
2009
Engelska.
Ingår i: Hydrobiologia.. - : Springer Science and Business Media LLC. - 0018-8158 .- 1573-5117. ; 619:1, s. 11-25
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The objective of this study was to evaluate a novel fully implantable radio-based blood flow biotelemetry system which allows simultaneously measurement of blood flow on two channels and temperature on one channel, in fish. These are the first recordings of blood flow from free-swimming fish, showing that the system is capable of recording blood flow in the ventral aorta (cardiac output) and celiacomesenteric artery (gastrointestinal blood flow) in green sturgeon Acipenser medirostris exposed to a series of different stimuli for up to 7 days after implantation. The results showed stable base line recordings and blood flow was used to calculated heart rate (f H) and stroke volume (V s). It was possible to reproduce the same type of responses as has previously been reported during exposure to hypoxia, temperature, stress and feeding. The mass of our implant was less than 2% of the body mass which is well within the recommended sizes for surgically implanted telemetry transmitters and it fitted easily within the abdominal cavity of the sturgeon. A fully implantable system minimizes the risk of infection/expulsion and maximizes the likelihood that the studied fish will behave naturally and be treated normally by surrounding fish. The use of biotelemetry in basic comparative physiology and applied animal ecology could help scientists to collect information that has previously been challenging to obtain and to open the possibility for new types of physiological and ecophysiological studies.

Ämnesord

NATURVETENSKAP  -- Biologi -- Zoologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Zoology (hsv//eng)
NATURVETENSKAP  -- Biologi -- Mikrobiologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Microbiology (hsv//eng)
NATURVETENSKAP  -- Biologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences (hsv//eng)

Nyckelord

Biotelemetry - Blood flow
Temperature
Doppler flow
Chronic measurements

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy