SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/83891"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/83891" > Accurate tissue are...

Accurate tissue area measurements with considerably reduced radiation dose achieved by patient-specific CT scan parameters

Brandberg, John, 1966 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Clinical Sciences,Institute of Medicine, Department of Molecular and Clinical Medicine
Lönn, Lars, 1956 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institutionen för kliniska vetenskaper,Institute of Medicine, Department of Molecular and Clinical Medicine,Institute of Clinical Sciences
Bergelin, Eva, 1950 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
visa fler...
Sjöström, Lars (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
Forssell-Aronsson, Eva, 1961 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Starck, Göran (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
visa färre...
 (creator_code:org_t)
British Institute of Radiology, 2008
2008
Engelska.
Ingår i: British Journal of Radiology. - : British Institute of Radiology. - 1748-880X .- 0007-1285. ; 81:970, s. 801-8
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A low-dose technique was compared with a standard diagnostic technique for measuring areas of adipose and muscle tissue and CT numbers for muscles in a body composition application. The low-dose technique was intended to keep the expected deviation in the measured area of adipose and muscle tissue to <1% of the total tissue area. The largest diameter of the patient determined the parameters for the low-dose technique. 17 patients - chosen to cover a wide range of diameters (31-47 cm) for both abdomen and thighs - were examined using both techniques. Tissue areas were compared, as were CT numbers for muscle tissue. Image noise was quantified by standard deviation measurements. The area deviation was <1%, except in the smallest subjects, in whom it was <2%. The integral radiation dose of the low-dose technique was reduced to 2-3% for diameters of 31-35 cm and to 7.5-50% for diameters of 36-47 cm as compared with the integral dose by the standard diagnostic technique. The CT numbers of muscle tissue remained unchanged with reduced radiation dose. Image noise was on average 20.9 HU (Hounsfield units) for subjects with diameters of 31-35 cm and 11.2 HU for subjects with diameters in the range of 36-47 cm. In conclusion, for body composition studies with CT, scan protocols can be adjusted so that the integral dose is lowered to 2-60% of the standard diagnostic technique at our centre without adversely altering area measurements of adipose and muscle tissue and without altering CT numbers of muscle tissue.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Adipose Tissue/*radiography
Body Composition/physiology
Body Weight/physiology
Clinical Protocols
Dose-Response Relationship
Radiation
Female
Humans
Image Processing
Computer-Assisted/methods
Male
Radiography
Abdominal/methods
Sensitivity and Specificity
Thigh/radiography
Tomography
X-Ray Computed/*methods

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy