SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/86183"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/86183" > The role of surface...

The role of surface chemistry and surface topography of osseointegrated titanium implant: strength and rate of osseointegration.

Sul, Young-Taeg, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Kang, Byung-Soo (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Johansson, Carina B., 1955 (författare)
visa fler...
Um, HS (författare)
Park, C (författare)
Albrektsson, Tomas, 1945 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
visa färre...
 (creator_code:org_t)
Wiley, 2009
2009
Engelska.
Ingår i: Journal of Biomedical Materials Research Part A. - : Wiley. - 1549-3296 .- 1552-4965. ; 89A:4, s. 942-950
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The present study investigated the effects of surface chemistry and topography on the strength and rate of osseointegration of titanium implants in bone. Three groups of implants were compared: (1) machine-turned implants (turned implants), (2) machine-turned and aluminum oxide-blasted implants (blasted implants), and (3) implants that were machine-turned, aluminum oxide-blasted, and processed with the micro-arc oxidation method (Mg implants). Three and six weeks after implant insertion in rabbit tibiae, the implant osseointegration strength and rate were evaluated. Surface chemistry revealed characteristic differences of nine at.% Mg for Mg implants and 11 at.% Al for blasted implants. In terms of surface roughness, there was no difference between Mg implants and blasted implants in developed surface ratio (Sdr; p = 0.69) or summit density (Sds; p = 0.96), but Mg implants had a significantly lower arithmetic average height deviation (Sa) value than blasted implants (p = 0.007). At both 3 and 6 weeks, Mg implants demonstrated significantly higher osseointegration strength compared with turned (p = 0.0001, p = 0.0001) and blasted (p = 0.0001, p = 0.035) implants, whereas blasted implants showed significantly higher osseointegration than turned implants at 6 weeks (p = 0.02) but not at 3 weeks (p = 0.199). The present results not only support the hypothesis that biochemical bonding facilitates rapid and strong integration of implants in bone, but also provide evidence for biochemical bonding theory previously proposed by Sul. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2008

Ämnesord

LANTBRUKSVETENSKAPER  -- Veterinärmedicin -- Medicinsk biovetenskap (hsv//swe)
AGRICULTURAL SCIENCES  -- Veterinary Science -- Medical Bioscience (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Cell- och molekylärbiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Cell and Molecular Biology (hsv//eng)

Nyckelord

strength and rate of osseointegration
titanium implant
surface topography
surface chemistry
bone

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy