SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/97499"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/97499" > High-resolution com...

High-resolution computed tomography with 16-row MDCT: A comparison regarding visibility and motion artifacts of dose-modulated thin slices and "step and shoot" images

Vikgren, Jenny, 1957 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Johnsson, Åse (Allansdotter), 1966 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Flinck, Agneta, 1953 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
visa fler...
Kheddache, Susanne, 1949 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Milde, Helén, 1957 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Båth, Magnus, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
visa färre...
 (creator_code:org_t)
2008-09-01
2008
Engelska.
Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 49:7, s. 755-760
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Dose modulation can be used to reduce the radiation dose in computed tomography (CT) examinations while still obtaining the necessary diagnostic image quality. Multidetector-row computed tomography (MDCT) provides the possibility of simultaneous reconstruction of thin and thick slices from the same raw data. Purpose: To compare thin slices reconstructed from a dose-modulated helical acquisition and conventional high-resolution computed tomography (HRCT) images taken with the “step and shoot” technique in terms of visibility and motion artifacts, in order to investigate the possibility of excluding “step and shoot” acquisition from the HRCT examination. Material and Methods: Twenty patients were examined by a dose-modulated helical acquisition, “MDCT smart mA,” and by a noncontiguous cross-sectional high-resolution 16-row MDCT examination, “MDCT step and shoot.” Images from four anatomical levels, made anonymous regarding identity and technical data, were analyzed in random order by four thoracic radiologists. Results: “MDCT smart mA” was worse than “MDCT step and shoot” in terms of visibility. Concerning motion artifacts, “MDCT smart mA” was better than “MDCT step and shoot.” Conclusion: Thin images reconstructed from a dose-modulated 16-row helical MDCT acquisition (“MDCT smart mA”), as performed in our study, do not provide sufficient image quality regarding visibility compared to the “MDCT step and shoot” technique for the latter technique to be excluded from the HRCT examination.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

diffuse lung-disease
section ct
radiology
quality

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy