SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/97503"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/97503" > Measurement of Lowe...

Measurement of Lower-Leg Volume Change by Quantitative Computed Tomography

Angelhed, Jan-Erik, 1948 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Strid, L. (författare)
Gothenburg University,Göteborgs universitet,Wallenberglaboratoriet,Wallenberg Laboratory
Bergelin, Eva, 1950 (författare)
Gothenburg University,Göteborgs universitet,Wallenberglaboratoriet,Wallenberg Laboratory
visa fler...
Fagerberg, Björn, 1943 (författare)
Gothenburg University,Göteborgs universitet,Wallenberglaboratoriet,Wallenberg Laboratory
visa färre...
 (creator_code:org_t)
2008-11-01
2008
Engelska.
Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 49:9, s. 1024-1030
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Lower-leg edema is a common symptom in many diseases. A precise method with low variability for measurement of edema is warranted in order to obtain optimal conditions for investigation of treatment effects. Purpose: To evaluate computed tomography for precise measurement of lower-leg muscle and adipose tissue volumes using a very low level of effective radiation dose. Material and Methods: Eleven volunteers were examined three times during 1 day, either as two consecutive examinations in the morning and one single examination in the afternoon, or as one examination in the morning and two in the afternoon. Eleven scans with computed tomography were made at each examination, and lower-leg volumes were calculated from automatically measured scan areas and interscan distances. Volumes for muscle, adipose tissue, and bone were calculated separately. Minimal radiation dose was used. Results: Mean difference between the repeated examinations was −0.1 ml for total volume, −1.4 ml for muscle, and 1.6 ml for adipose tissue volume. The corresponding 95% confidence intervals were −6.5 to 6.0 ml, −3.5 to 6.5 ml, and −7.0 to 4.0 ml, respectively. The resulting effective dose was 0.5 µSv to one leg. Conclusion: Computed tomography can be used as a precise quantitative method to measure small volume changes of the lower leg as a whole, and separately for muscle and adipose tissue. The results were obtained with a negligible effective dose, lower than that delivered by modern fan-beam dual-energy X-ray absorptiometry whole-body examinations and equal to a few hours of background radiation.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

lower-limb
edema
fat

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Angelhed, Jan-Er ...
Strid, L.
Bergelin, Eva, 1 ...
Fagerberg, Björn ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Acta Radiologica
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy