SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:01c93c47-26fb-4d47-81bd-d05bdefc7807"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:01c93c47-26fb-4d47-81bd-d05bdefc7807" > The influence of a ...

The influence of a low-molecular hydrophobic solute on the flux of poly-sulphone ultrafiltration membranes with different cut-off

Lindau, J (författare)
Jönsson, Ann-Sofi (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
Wimmerstedt, Roland (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
 (creator_code:org_t)
1995
1995
Engelska.
Ingår i: Journal of Membrane Science. - 0376-7388. ; 106:1-2, s. 9-16
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this study the influence of a low-molecular hydrophobic solute on the Bur of a hydrophilic regenerated cellulose membrane and hydrophobic polysulphone membranes with different nominal molecular weight cut-off, NMWCO, was investigated. Octanoic acid was used as a model substance because it is considerably smaller than the NMWCO of all the membranes used in the investigation. Octanoic acid was found to decrease the flux of the polysulphone membranes considerably. The decrease was dependent on the NMCWO, although in all cases the NMWCO is many times larger than the size of the octanoic acid molecules. It is also shown that the Bur of the hydrophilic membrane, with a NMWCO of the same size as one of the denser hydrophobic membranes, is unaffected by the octanoic acid. The cross-sections of both used and unused membranes were examined in a scanning electron microscope (SEM). No visual difference was observed between the used and unused membrane samples. Analysis of the membranes with Fourier transform infrared spectroscopy (FTIR) showed that octanoic acid remained in the membranes even after thorough cleaning.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Kemiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Chemical Engineering (hsv//eng)

Nyckelord

ULTRAFILTRATION
FOULING
ADSORPTION
FATTY ACID
CLEANING

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Lindau, J
Jönsson, Ann-Sof ...
Wimmerstedt, Rol ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Kemiteknik
Artiklar i publikationen
Journal of Membr ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy