Repeatability of sonographic measurements in clubfeet

Aurell, Ylva (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Adlercreutz, C (författare)
Andriesse, Hanneke (författare)
Lund University,Lunds universitet,Människan i rörelse: hälsa och rehabilitering,Forskargrupper vid Lunds universitet,Human Movement: health and rehabilitation,Lund University Research Groups
visa fler...
Jonsson, Kjell (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
visa färre...
 (creator_code:org_t)
2016-08-30
2004
Engelska.
Ingår i: Acta Radiologica. - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 45:6, s. 622-627
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To assess the intra- and interobserver agreement of ultrasound assessment of clubfoot patho-anatomy in early childhood. Material and Methods: Seventeen clubfeet in 12 children were sequentially scanned by 2 examiners and repeat assessments were carried out independently. Three well-defined imaging planes were chosen to evaluate navicular displacement: the medial malleolus-navicular (MM-N) distance, soft tissue thickness, talar deformity and the calcaneocuboid (C-C) distance. Intra- and interobserver agreement was analysed using Cohen's kappa for the discrete variables and by Bland-Altman's graphic technique for measurements. Results: Kappa values for intra-observer agreement were 0.82 for navicular displacement, 0.93 for "talar head pointing laterally", and 0.70 for medial deviation of the talar neck. The corresponding interobserver kappa values were 0.70, 0.68, and 0.36. The mean difference between the two observers for the MM-N distance was 0.42+/-3.0 mm and for the soft tissue thickness 0.35+/-2.0 mm; the C-C distance showed a mean interobserver distance of 0.0+/-2.8 mm. Conclusion: The imaging planes used to study the talo-navicular and calcaneo-cuboid relationships are reproducible and relatively easy to learn. Intra- and interobserver assessments were acceptable for MM-N distance, soft tissue thickness, navicular displacement and "talar head pointing laterally", but questionable for the C-C distance and medial deviation of the talar neck.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

ultrasound
repeatability
clubfoot
observer variation

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Aurell, Ylva
Adlercreutz, C
Andriesse, Hanne ...
Jonsson, Kjell
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Acta Radiologica
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy