SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:09ead7ab-2178-4c30-bd02-fe049881c336"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:09ead7ab-2178-4c30-bd02-fe049881c336" > Monitoring bispheno...

Monitoring bisphenol A and its biodegradation in water using a fluorescent molecularly imprinted chemosensor.

Wu, Ya-Ting (författare)
Liu, Yan-Jie (författare)
Gao, Xia (författare)
visa fler...
Gao, Kai-Chun (författare)
Xia, Hu (författare)
Luo, Mi-Fang (författare)
Wang, Xue-Juan (författare)
Ye, Lei (författare)
Lund University,Lunds universitet,Tillämpad biokemi,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Pure and Applied Biochemistry,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Shi, Yun (författare)
Lu, Bin (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2015
2015
Engelska.
Ingår i: Chemosphere. - : Elsevier BV. - 1879-1298 .- 0045-6535. ; 119, s. 515-523
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this paper, we present a simple and rapid method for monitoring bisphenol A (BPA) and its biodegradation in environmental water using a fluorescent molecularly imprinted polymer chemosensor (fMIPcs). A fluorescent molecularly imprinted polymer (fMIP) was first synthesized by precipitation polymerization method using BPA as template, dansyl methacrylate as functional monomer. Then a fMIPcs was constructed by combining the fMIP with a fluorescent microplate reader. The fMIPcs displayed selective, concentration-dependent fluorescence quenching in response to BPA in water even in the existence of interferences, thereby allowing reliable high through-put quantification of BPA via simple fluorescence measurements. The fMIPcs was able to directly quantify BPA (from 10 to 2000μgL(-1)) in different environmental water samples (distilled water, distilled water containing heavy metals and humic acid, tap water, and river water) with high accuracy, and to monitor BPA biodegradation in real-time. Using the fMIPcs, it was possible to achieve fast analytical results with lower limit of detection for BPA (3μgL(-1)) from smaller sample volume (250μL), which are superior to many relevant methods reported in the literature. Moreover, BPA levels and biodegradation rates measured by fMIPcs are comparable to the instrument-based method (HPLC). The fMIPcs developed in this work offers a new solution for simple, rapid, accurate and high through-put BPA quantification, and makes it possible to monitor BPA biodegradation in real time.

Ämnesord

NATURVETENSKAP  -- Geovetenskap och miljövetenskap -- Miljövetenskap (hsv//swe)
NATURAL SCIENCES  -- Earth and Related Environmental Sciences -- Environmental Sciences (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy