Ventilation solutions in clothing

Kuklane, Kalev (författare)
Lund University,Lunds universitet,Ergonomi och aerosolteknologi,Institutionen för designvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Ergonomics and Aerosol Technology,Department of Design Sciences,Departments at LTH,Faculty of Engineering, LTH
Gao, Chuansi (författare)
Lund University,Lunds universitet,Ergonomi och aerosolteknologi,Institutionen för designvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Ergonomics and Aerosol Technology,Department of Design Sciences,Departments at LTH,Faculty of Engineering, LTH
Holmér, Ingvar (författare)
Lund University,Lunds universitet,Ergonomi och aerosolteknologi,Institutionen för designvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Ergonomics and Aerosol Technology,Department of Design Sciences,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Bartkowiak, Grazyna (redaktör/utgivare)
Frydrych, Iwona (redaktör/utgivare)
Pawlowa, Maria (redaktör/utgivare)
visa färre...
 (creator_code:org_t)
2012
2012
Engelska 8 s.
Ingår i: Innovations in textile materials & protective clothing. - 9788372834935 ; , s. 205-212
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • There are several solutions to keep the workers at good thermal state at hot or cold workplaces, for example, PCM (phase change materials) and ice; electrically heated clothing; increase/decrease clothing insulation, e.g. with smart textiles; water based cooling/heating; air based systems, ventilated clothes. Following methods can be used to increase the ventilation in the clothes: use of air permeable clothes; increase possibilities for ventilation (design solutions); active ventilation (e.g. fans) etc. Polluted atmosphere may not allow to use the methods above. Ventilation in protective clothing, e.g. for CBRN protection may require inlet air filtering or a separate (compressed) air source. Various solutions have been tested with natural and forced ventilations, and flow rates. Dry and wet tests were carried out. Ventilation is an effective way to increase heat loss. Ventilation utilizes body own capacity (sweating) to regulate heat loss. At extremely high temperatures considerable air flows are required for sufficient cooling: 100 l/min may not be enough. The larger is the ventilated skin area, the more effective it is due to enhanced evaporation.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Produktionsteknik, arbetsvetenskap och ergonomi (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Production Engineering, Human Work Science and Ergonomics (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy