SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:0f963837-bc8a-4025-8f36-7d301f2c81a7"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:0f963837-bc8a-4025-8f36-7d301f2c81a7" > Repeatability of me...

Repeatability of measurements of oxygen consumption, heart rate and Borg's scale in men during ergometer cycling.

Wergel-Kolmert, Ulla (författare)
Lund University,Lunds universitet,Människan i rörelse: hälsa och rehabilitering,Forskargrupper vid Lunds universitet,Human Movement: health and rehabilitation,Lund University Research Groups
Wisén, Anita (författare)
Lund University,Lunds universitet,Människan i rörelse: hälsa och rehabilitering,Forskargrupper vid Lunds universitet,Human Movement: health and rehabilitation,Lund University Research Groups
Wohlfart, Björn (författare)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
 (creator_code:org_t)
2002
2002
Engelska.
Ingår i: Clinical Physiology and Functional Imaging. - 1475-0961. ; 22:4, s. 261-265
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The coefficient of repeatability (COR), expressed as 2-SD of differences, was calculated between two measurements of oxygen consumption (V O2), heart rate (HR) and rating of perceived exertion (RPE) during ergometer cycling by men. The two sets of measurements were performed 5 to 6 weeks apart. Nineteen healthy men performed an incremental maximal exercise test on an ergometer cycle. The load started at 50 W and increased by 5 W 20 s-1 until exhaustion was reached. At 40% of the individual maximum load of the pretest, the load was kept constant for 4 min in order to reach steady state. Gas measurements were recorded continuously by computerized instrumentation. The HR was monitored with electrocardiography (ECG) and the perceived exertion was evaluated using Borg's scale. The COR of V O2 at sub-maximal load was 14% and at maximum load 11%. The values in absolute figures were 209 and 332 ml min-1. The corresponding COR of the HR was 16% at sub-maximum load and 6% at maximum load, and an evaluation of the perceived exertion yielded CORs in absolute values of 4.8 and 1.3, respectively. The COR for V O2, HR and ratings of perceived exertion when cycling on an ergometer cycle thus indicate a better agreement between the measurements at maximum load. The COR of the heart at sub-maximal loads must be kept in mind when using HR for estimation of V O2max. The reported findings should be considered when using tests on an ergometer cycle for evaluating exercise capacity.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)

Nyckelord

physical capacity
perceived exertion
oxygen uptake
exercise test
heart rate

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Wergel-Kolmert, ...
Wisén, Anita
Wohlfart, Björn
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinska och f ...
och Fysiologi
Artiklar i publikationen
Clinical Physiol ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy