SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:0fe6cf7a-1a17-43cb-80a0-6d9df5d92075"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:0fe6cf7a-1a17-43cb-80a0-6d9df5d92075" > Extracting syringe ...

Extracting syringe for extraction of phthalate esters in aqueous environmental samples

Bergström, Staffan (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Barri, Thaer (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Norberg, Jan (författare)
visa fler...
Jönsson, Jan Åke (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Mathiasson, Lennart (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
Elsevier BV, 2007
2007
Engelska.
Ingår i: Analytica Chimica Acta. - : Elsevier BV. - 1873-4324 .- 0003-2670. ; 594:2, s. 240-247
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The use of the extracting syringe (ESy), a fully automated membrane-based extraction technique, for analysis of phthalate esters in complex aqueous samples has been investigated. The ESy, working as an autosampler that combines the extraction process and injection into the gas chromatograph (GC) in one single step, is placed on top of the GC equipped with a flame ionisation detector. The aqueous samples are loaded in a tray and automatically extracted by employing microporous membrane liquid-liquid extraction principle. After the extraction, the extract is directly injected into the GC's programmable temperature vaporisation injector. Six different phthalate esters were used as model compounds. Four extraction solvents were tested and the addition of sample organic modifier was examined. Toluene was the optimal solvent to use for extraction. Due to the large variation in polarity of phthalate esters, 50% methanol as organic modifier had to be added to the samples so as to extract the most nonpolar phthalate esters; di-2-ethylhexylphthalate and di-n-octylphthalate, whereas the other four relatively polar phthalate esters were extracted from unmodified samples. No significant difference between extraction of river water, leachate water from a landfill and reagent water was noted, except for minor deviations. The extraction time was 20 min for extraction of a 1-mL sample, resulting in a good linearity for all aqueous media investigated, good enrichment factors (54-110 folds) and low LOD values (0.2-10 ng mL(-1)) and relative standard deviation (%R.S.D.; 0.9-3.7%).

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

leachate water
environmental analysis
membrane extraction
extracting syringe
microporous membrane
phthalate esters
liquid-liquid extraction
gas chromatography

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy