Sökning: id:"swepub:oai:lup.lub.lu.se:10ed56a3-03e5-488d-97bf-8e28f0755379" >
Direct action on th...
Direct action on the molecule is one of several mechanisms by which ultrasound enhances the fibrinolytic effects of reteplase.
-
- Madsen-Härdig, Bjarne (författare)
- Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Persson, Hans W (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
- Olsson, Bertil (författare)
- Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
(creator_code:org_t)
- 2006
- 2006
- Engelska.
-
Ingår i: Blood Coagulation and Fibrinolysis. - 1473-5733. ; 17:2, s. 105-112
- Relaterad länk:
-
http://www.ncbi.nlm....
-
visa fler...
-
https://lup.lub.lu.s...
-
visa färre...
Abstract
Ämnesord
Stäng
- Enhanced fibrinolytic reperfusion therapy may improve the outcome in embolic stroke, where ultrasound exposure has been shown to be one option. We recently verified that the fibrinolytic properties of streptokinase were modulated following ultrasound exposure of the molecule. We have now explored this possibility following ultrasound exposure of the reteplase molecule. The effects on clot lysis of reteplase and ultrasound both separately and in combination were studied by evaluating cumulated release of haemoglobin from whole blood clots following 1 h of exposure. Specifically, we investigated how clot lysis was modulated following pulsed 1 MHz ultrasound pre-exposure of the reteplase solution at intensities ranging between 0.125 and 4 W/cm2 spatial-average temporal-average intensity (SATA) and the effects of reteplase following 1 h of pre-exposure of clots to ultrasound at high intensity (4 W/cm2SATA). Significant enhancement of clot lysis during concomitant reteplase and pulsed ultrasound exposure were observed in two intensity ranges: 0.125-0.25 and 2-4 W/cm2SATA. Pre-exposing reteplase solution to ultrasound significantly increased clot lysis only in the lower intensity range. At high ranges, pre-exposure of clots to ultrasound was followed by an increased fibrinolytic action of reteplase. Pre-exposing reteplase solution to low-intensity ultrasound induced changes in the reteplase molecule that enhanced its fibrinolytic effects. Although this effect disappeared at moderately higher ultrasound intensity, the pre-exposure of clots to ultrasound of higher intensity induced increased fibrinolytic effects of reteplase solution.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Hematologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Hematology (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas