Improved Tracking Performance in High Frame Rate Imaging Using Iterative Phase Tracking
-
- Erlöv, Tobias (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
- Larsson, Roger (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Ergonomi och aerosolteknologi,Institutionen för designvetenskaper,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Ergonomics and Aerosol Technology,Department of Design Sciences,Faculty of Engineering, LTH
-
- Boni, Enrico (författare)
- University of Florence
-
visa fler...
-
- Ramalli, Alessandro (författare)
- University of Florence,Catholic University of Leuven
-
- Rydén Ahlgren, Åsa (författare)
- Lund University,Lunds universitet,Klinisk fysiologi och nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Clinical Physiology and Nuclear Medicine, Malmö,Lund University Research Groups
-
- Cinthio, Magnus (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
visa färre...
-
(creator_code:org_t)
- 2019
- 2019
- Engelska 4 s.
-
Ingår i: 2019 IEEE International Ultrasonics Symposium (IUS). - 1948-5719 .- 1948-5727. - 9781728145969 - 9781728145976 ; 2019, s. 2158-2161
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- High frame rate ultrasound imaging is necessary to enable tracking of rapid dynamic events such as the carotid pulse wave velocity. Several studies have shown that it is feasible to use motion tracking methods that are applied on standard ultrasound frame rates also on very high frame rates. However, few studies have addressed the issue of accumulated tracking errors over vast numbers of frames during Lagrangian tracking. These could stem from e.g. limited signal-to-noise ratio often resulting from the use of plane wave imaging. One recently proposed solution was to combine motion tracking with an iterative tracking scheme. The purpose of this study has been to evaluate if the iterative tracking scheme could be exploited to increase the robustness of a phase-based tracking method in high frame rate plane wave imaging to track the carotid artery wall diameter. The results showed the iterative tracking scheme to give increased robustness with significantly (p<0.0003) less differences in measured lumen diameters between adjacent lines. Thus, this study enforces the suggestion to use the iterative tracking scheme during Lagrangian tracking in high frame rate imaging.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Image Processing (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- Tracking
- Imaging
- Ultrasonic imaging
- Iterative methods
- Carotid arteries
- Ultrasonic variables measurement
- Robustness
- High frame rate imaging
- Motion estimation
- Iterative tracking scheme
- Accumulated errors