Sökning: id:"swepub:oai:lup.lub.lu.se:13d73a26-1b94-4dd4-bc09-b69d1842b42e" > Inflammatory reacti...

Inflammatory reaction dependence on implant localization in rat soft tissue models

Rosengren, Agneta (författare)
Lund University,Lunds universitet,Institutionen för experimentell medicinsk vetenskap,Medicinska fakulteten,Department of Experimental Medical Science,Faculty of Medicine
Danielsen, Nils (författare)
Lund University,Lunds universitet,Neurala gränsytor,Forskargrupper vid Lunds universitet,Neural Interfaces,Lund University Research Groups
Bjursten, Lars Magnus (författare)
Lund University,Lunds universitet,Institutionen för experimentell medicinsk vetenskap,Medicinska fakulteten,Department of Experimental Medical Science,Faculty of Medicine
 (creator_code:org_t)
1997
1997
Engelska.
Ingår i: Biomaterials. - 1878-5905. ; 18:14, s. 979-987
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This study compares two different implantation models in soft tissue in rat abdominal wall with regard to inflammatory reactions. Titanium rods and discs, penetrating or not penetrating the peritoneal wall respectively, were implanted. After 3, 10 or 30 days the distribution of monocytes/macrophages and cytokines (interleukin-1 and transforming growth factor-beta) in the tissue adjacent to the implants was investigated under immunohistochemistry. The macrophage-specific antibody, ED1, was used for the identification of newly recruited macrophages and the ED2 antibody was used for the mature tissue macrophages. After 10 days the non-penetrating implants had a larger number of cells close to the implant than the penetrating implants. The opposite was seen after 30 days implantation, with a larger number of cells around the penetrating implants. At all time intervals the penetrating implants had a thicker reactive capsule. The cytokines interleukin-1beta and transforming growth factor-beta could be detected in the reactive tissue adjacent to both types of implants, without obvious differences for the two implant situations. The biocompatibility of a material appears to be influenced by the localization of the implant. In addition, it seems to be of importance to extend the follow-up periods further, as we cannot assume that steady state is reached at 30 days implantation.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Industriell bioteknik -- Bioteknisk apparatteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Industrial Biotechnology -- Bioengineering Equipment (hsv//eng)

Nyckelord

Titanium
peritoneal implants
macrophages
immunohistochemistry
soft tissue

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Rosengren, Agnet ...
Danielsen, Nils
Bjursten, Lars M ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Industriell biot ...
och Bioteknisk appar ...
Artiklar i publikationen
Biomaterials
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy