Generation of X-rays For Medical Imaging By High-power Lasers - Preliminary-results
-
Herrlin, K (författare)
-
Svahn, G (författare)
-
Olsson, C (författare)
-
visa fler...
-
Pettersson, H (författare)
-
Tillman, C (författare)
-
- Persson, Anders (författare)
- Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
-
- Wahlström, Claes-Göran (författare)
- Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
-
- Svanberg, Sune (författare)
- Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
-
visa färre...
-
(creator_code:org_t)
- 1993
- 1993
- Engelska.
-
Ingår i: Radiology. - 1527-1315. ; 189:1, s. 65-68
- Relaterad länk:
-
http://radiology.rsn...
-
visa fler...
-
https://lup.lub.lu.s...
-
visa färre...
Abstract
Ämnesord
Stäng
- PURPOSE: To evaluate the use of x-ray imaging performed with a high-power laser system in biologic and medical studies. MATERIALS AND METHODS: A compact terawatt laser system based on chirped pulse amplification in titanium-doped sapphire was used. X rays were generated by irradiating a high-atomic-number target (tantalum). RESULTS: When photons with an energy below 10 keV were removed with use of 3 mm of aluminum, the half-value layer in aluminum for the remaining x rays was approximately 10 mm. The x-ray source allowed performance of biologic magnification radiography. Star-pattern tests indicated an equivalent focal spot size of less than 60 mum. Exposures of a single pulse could be obtained. The duration of a single x-ray pulse was estimated to be of the order of picoseconds. CONCLUSION. With use of subpicosecond laser pulses, x-ray generation can occur with a smaller equivalent focal spot size than with conventional x-ray sources.