SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:1a424bdb-784f-4454-afde-e701d7478bdd"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:1a424bdb-784f-4454-afde-e701d7478bdd" > Improving thermal c...

Improving thermal comfort in an orthopaedic aid: better boston brace for scoliosis patients

Kuklane, Kalev (författare)
Lund University,Lunds universitet,Ergonomi och aerosolteknologi,Institutionen för designvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Ergonomics and Aerosol Technology,Department of Design Sciences,Departments at LTH,Faculty of Engineering, LTH
Heidmets, Sixten (författare)
Johansson, Tony (författare)
visa fler...
Fan, Jintu (redaktör/utgivare)
visa färre...
 (creator_code:org_t)
2006
2006
Engelska 9 s.
Ingår i: Thermal Manikins and Modelling. - 9623675348 ; , s. 343-351
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Scoliosis is an S-shaped sideways curvature of the spine leading to the shape change of the torso Idiopathic scoliosis is one form of this disease with unknown aetiology. 300 children out of 100 000 need treatment. Treatment duration is till the end of the patient’s growth age (till the ossification of the skeleton) and the brace should be worn 23 hours a day. Problems with brace are: heat, moist, heavy, stiff, affects skin, odor, medical look, etc. Thus, the main objectives were to improve heat and moisture dissipation from the brace. However, it was to be kept in mind that the brace is an orthopaedic aid and its positive effect has been documented and proven over decades. A new brace was designed but the question was: Is it better? To answer the question the tests on the thermal manikin were carried out with constant surface temperature mode, stable temperature and humidity in the climatic chamber, recording of power input (heat loss) and having manikin on weighting scale for continuous recording of evaporation. With manikin tests we could show that the dry insulation of old and new brace was similar. There was 30 % better moisture dissipation from new compared to the old brace. Heat dissipation from new brace was most probably improved due to higher evaporative heat losses and optimizing the openings may improve ventilation even more. In addition, following positive effects were achieved: the brace looks lighter and is more airy and skin friendly because of the openings, the new brace is by 3 mm thinner, therefore more fitting under clothing, openings and the thinner inner lining reduced the weight of the brace, the changeable inner lining makes frequent machine washing possible, but also use of linings in different colour.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Produktionsteknik, arbetsvetenskap och ergonomi (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Production Engineering, Human Work Science and Ergonomics (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Nyckelord

scoliosis
thermal comfort
thermal manikin Tore
Effective insulation
boston brace

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Kuklane, Kalev
Heidmets, Sixten
Johansson, Tony
Fan, Jintu
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Produktionstekni ...
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Ortopedi
Artiklar i publikationen
Thermal Manikins ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy