SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:1e522598-ee4a-4777-b466-d0e605f6e4fc"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:1e522598-ee4a-4777-b466-d0e605f6e4fc" > Simultaneous detect...

Simultaneous detection of the release of glutamate and nitric oxide from adherently growing cells using an array of glutamate and nitric oxide selective electrodes

Castillo Leon, Jaime (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Isik, S (författare)
Blochl, A (författare)
visa fler...
Pereira-Rodrigues, N (författare)
Bedioui, F (författare)
Csöregi, Elisabeth (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Schuhmann, W (författare)
Oni, J (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2005
2005
Engelska.
Ingår i: Biosensors & Bioelectronics. - : Elsevier BV. - 1873-4235 .- 0956-5663. ; 20:8, s. 1559-1565
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The simultaneous detection of nitric oxide and glutamate using an array of individually addressable electrodes, in which the individual electrodes in the array were suitably modified with a highly sensitive nitric oxide sensing chemistry or a glutamate oxidase/redox hydrogel-based glutamate biosensor is presented. In a sequence of modification steps one of the electrodes was covered first with a positively charged Ni porphyrin entrapped into a negatively charged electrodeposition paint followed by the manual modification of the second working electrode by a bienzyme sensor architecture based on crosslinked redox hydrogels with entrapped peroxidase and glutamate oxidase. Adherently growing C6-glioma cells were grown on membrane inserts and placed in close distance to the modified sensor surfaces. The current responses recorded at each electrode after stimulation of glutamate and NO release by means of K+ and bradykinin clearly demonstrate the ability of the individual electrode in the array to detect the analyte towards which its sensitivity and selectivity was targeted without interference from the neighbouring electrode or other analytes present in the test mixture.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

nitric oxide
glutamate oxidase
electrode array
biosensor
modified
electrodes
transmitter release

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy