Accuracy investigations for volumetric head-motion navigators with and without EPI at 7 T

Andersen, Mads (författare)
Lund University,Lunds universitet,Lund University Bioimaging Center,Medicinska fakulteten,Faculty of Medicine,Philips Healthcare, Denmark
Laustsen, Malte (författare)
Technical University of Denmark,Copenhagen University Hospital
Boer, Vincent (författare)
Copenhagen University Hospital
 (creator_code:org_t)
2022-05-16
2022
Engelska 14 s.
Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 0740-3194 .- 1522-2594. ; 88:3, s. 1198-1211
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: Accuracy investigation of volumetric navigators for motion correction, with emphasis on geometric EPI distortions at ultrahigh field. Methods: High-resolution Dixon images were collected in different head positions and reconstructed to water, fat, T2*, and B0 maps. Resolution reduction was performed, and the T2* and B0 maps were used to apply effects of TE and EPI distortions to simulate various volumetric water and fat navigators. Registrations of the simulated navigators were compared with registrations of the original high-resolution images. Results: Increased accuracy was observed with increased spatial resolution for non-EPI navigators. When using EPI, the distortions had a negative effect on registration accuracy, which was most noticeable for high-resolution navigators. Parallel imaging helped to alleviate those caveats to a certain extent, and 5-fold acceleration gave close to similar accuracy to non-EPI in most cases. Shortening the TE by partial Fourier sampling was shown to be mostly beneficial, except for water navigators with long readout durations. The EPI blip direction had an influence on navigator accuracy, and positive blip gradient polarities (yielding mostly image stretching frontally) typically gave the best accuracy for water navigators, whereas no clear recommendation could be made for fat navigators. Generally, fat EPI navigators had lower accuracy than water EPI navigators with otherwise similar parameters. Conclusions: Echo planar imaging has been widely used for MRI navigators, but the induced distortions reduce navigator accuracy at ultrahigh field. This study can help protocol optimization and guide the complex tradeoff between resolution and EPI acceleration in navigator parameter setup.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

7 T
brain
EPI distortions
motion correction
multi-echo
navigators

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Andersen, Mads
Laustsen, Malte
Boer, Vincent
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk bildbe ...
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Magnetic Resonan ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy