SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:2bdbe307-ebff-4372-9c03-470aab60f480"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:2bdbe307-ebff-4372-9c03-470aab60f480" > Improved porous sil...

Improved porous silicon microarray based prostate specific antigen immunoassay by optimized surface density of the capture antibody

Lee, SangWook (författare)
Kim, Soyoun (författare)
Malm, Johan (författare)
Lund University,Lunds universitet,Klinisk kemi, Malmö,Forskargrupper vid Lunds universitet,Clinical Chemistry, Malmö,Lund University Research Groups
visa fler...
Jeong, Ok Chan (författare)
Lilja, Hans (författare)
Lund University,Lunds universitet,Klinisk kemi, Malmö,Forskargrupper vid Lunds universitet,Clinical Chemistry, Malmö,Lund University Research Groups
Laurell, Thomas (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
Elsevier BV, 2013
2013
Engelska.
Ingår i: Analytica Chimica Acta. - : Elsevier BV. - 1873-4324 .- 0003-2670. ; 796, s. 108-114
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA - prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5 ng mL(-1), 80 pg mL(1), and 800 fg mL(-1) when arraying the PSA antibody, H117 at the concentration 15 mu g mL(-1), 35 mu g mL(-1), and 154 mu g mL(-1), respectively. We further investigated PSA spiked into human female serum in the range of 800 fg mL(-1) to 500 ng mL(-1). The microarray showed a LOD of 800 fg mL(-1) and a dynamic range of 800 fg mL(-1) to 80 ng mL(-1) in serum spiked samples. (C) 2013 Elsevier B.V. All rights reserved.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

Antibody microarray
Porous silicon
Sandwich immunoassay
Prostate
specific antigen

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Lee, SangWook
Kim, Soyoun
Malm, Johan
Jeong, Ok Chan
Lilja, Hans
Laurell, Thomas
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
Artiklar i publikationen
Analytica Chimic ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy