SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:2c3ac22c-fdac-45f3-9f3f-563f663db60a"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:2c3ac22c-fdac-45f3-9f3f-563f663db60a" > A new generation of...

A new generation of algorithms for computerized threshold perimetry, SITA

Bengtsson, Boel (författare)
Chalmers University of Technology
Olsson, Jonny (författare)
Skåne University Hospital
Heijl, A (författare)
Chalmers University of Technology
visa fler...
Rootzén, H (författare)
Chalmers University of Technology,Lund University,Lunds universitet,Matematisk statistik,Matematikcentrum,Institutioner vid LTH,Lunds Tekniska Högskola,Mathematical Statistics,Centre for Mathematical Sciences,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2009-05-27
1997
Engelska 8 s.
Ingår i: Acta Ophthalmologica Scandinavica. - : Wiley. - 1395-3907. ; 75:4, s. 75-368
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: The purpose of this work was to develop a new family of test algorithms for computerized static threshold perimetry which significantly reduces test time without any reduction of data quality.METHODS: A comprehensive visual field model constructed from available knowledge of normal and glaucomatous visual fields is continuously updated during testing. The model produces threshold estimates and also estimates of the certainty to which the threshold is known at each point. Testing is interrupted at each test location at predetermined levels of threshold certainty. New time-saving methods are employed for estimation of false answers, and test pacing is optimized. After completion of the test, all threshold estimates are re-computed, taking into account the complete body of patient responses. Computer simulations were used to optimize the different parameters of the new algorithms, to evaluate the relative importance of those parameters, and to evaluate the performance of the algorithm as a whole in comparison with a standard algorithm.RESULTS: Simulated test results obtained with this algorithm were slightly more accurate than those of the Humphrey Full Threshold test algorithm. The number of simulated stimuli presented was reduced by an average of 29% in normal fields and 26% in glaucomatous fields. Actual clinical test time should be further reduced, since the influence of the improved timing algorithm was not included in the simulations.CONCLUSIONS: We applied new methods which take available knowledge of visual field physiology and pathophysiology into account, and employ modern computer-intensive mathematical methods for real time estimates of threshold values and threshold error estimates. In this way it was possible to design a family of testing algorithms which significantly reduced perimetric test time without any loss of quality in results.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Nyckelord

Algorithms
Computer Simulation
Diagnosis, Computer-Assisted
Glaucoma
Humans
Models, Biological
Reference Values
Sensory Thresholds
Visual Field Tests
Visual Fields

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Bengtsson, Boel
Olsson, Jonny
Heijl, A
Rootzén, H
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Oftalmologi
Artiklar i publikationen
Acta Ophthalmolo ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy