SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:2da3f822-7032-422c-900e-e4a29654ecd9"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:2da3f822-7032-422c-900e-e4a29654ecd9" > Temperature and con...

Temperature and concentration measurements in acetylene-nitrogen mixtures in the range 300-600 K using dual-broadband rotational CARS

Bood, J. (författare)
Lund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Bengtsson, P. E. (författare)
Lund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Aldén, Marcus (författare)
Lund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
 (creator_code:org_t)
2000
2000
Engelska 14 s.
Ingår i: Applied Physics B. - 0946-2171. ; 70:4, s. 607-620
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Pure rotational coherent anti-Stokes Raman scattering (CARS) experiments have been performed in acetylene for temperatures ranging from 294 to 582 K, and in mixtures of acetylene and nitrogen in the mole fraction range of 0.06-0.32 for acetylene at room temperature. The experimental spectra are evaluated by a least-square fitting to libraries of theoretically calculated spectra using two different Raman linewidth models, one with and one without dependence on the rotational quantum number J. It is found that a J-dependent model is favourable, both regarding temperature measurements in pure acetylene, and simultaneous acetylene concentration and temperature measurements in different mixtures of acetylene and nitrogen. For the temperature measurements performed in pure acetylene the temperature inaccuracy is generally less than 2% when the J-dependent model for the Raman linewidths is used. It is found that fitting the value of the non-resonant susceptibility significantly improves the quality of the spectral fits and is a requirement for high temperature accuracy with the present model. The evaluated concentrations show a maximum error of 13% on a relative scale. Potential sources of systematical errors both regarding measured temperatures and acetylene concentrations are discussed.

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Bood, J.
Bengtsson, P. E.
Aldén, Marcus
Artiklar i publikationen
Applied Physics ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy