SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:2deea18f-8d60-4db4-b2e4-860d8b903f9f"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:2deea18f-8d60-4db4-b2e4-860d8b903f9f" > Evaluation of inten...

Evaluation of intensity-modulated electron FLASH radiotherapy in a clinical setting using veterinary cases

Konradsson, Elise (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Radiotherapy Physics,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Lund University Research Groups
Szecsenyi, Rebecka Ericsson (författare)
Skåne University Hospital
Adrian, Gabriel (författare)
Lund University,Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Strålterapi,Sektion I,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Radiation therapy,Section I,Department of Clinical Sciences, Lund,Faculty of Medicine
visa fler...
Coskun, Mizgin (författare)
Lund University
Børresen, Betina (författare)
University of Copenhagen
Arendt, Maja Louise (författare)
University of Copenhagen
Erhart, Kevin (författare)
.decimal, LLC
Bäck, Sven Å.J. (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Radiotherapy Physics,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Medical Radiation Physics, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments
Petersson, Kristoffer (författare)
Lund University,Lunds universitet,Radiotherapy Physics,Forskargrupper vid Lunds universitet,Lund University Research Groups
Ceberg, Crister (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Radiotherapy Physics,Forskargrupper vid Lunds universitet,Rausinglaboratoriet i Lund - Tumörsektionen,LU profilområde: Ljus och material,Lunds universitets profilområden,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Lund University Research Groups,Rausing laboratory of Lund - Tumor section,LU Profile Area: Light and Materials,Lund University Profile areas
visa färre...
 (creator_code:org_t)
2023
2023
Engelska 11 s.
Ingår i: Medical Physics. - 0094-2405. ; 50:10, s. 6569-6579
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: The increased normal tissue tolerance for FLASH radiotherapy (FLASH-RT), as compared to conventional radiotherapy, was first observed in ultra-high dose rate electron beams. Initial clinical trials in companion animals have revealed a high risk of developing osteoradionecrosis following high-dose single-fraction electron FLASH-RT, which may be related to inhomogeneities in the dose distribution. In the current study, we aim to evaluate the possibilities of intensity-modulated electron FLASH-RT in a clinical setting to ensure a homogeneous dose distribution in future veterinary and human clinical trials. Methods: Our beam model in the treatment planning system electronRT (.decimal, LLC, Sanford, FL, USA) was based on a 10-MeV electron beam from a clinical linear accelerator used to treat veterinary patients with FLASH-RT in a clinical setting. In electronRT, the beam can be intensity-modulated using tungsten island blocks in the electron block cutout, and range-modulated using a customized bolus with variable thickness. Modulations were first validated in a heterogeneous phantom by comparing measured and calculated dose distributions. To evaluate the impact of intensity modulation in superficial single-fraction FLASH-RT, a treatment planning study was conducted, including eight canine cancer patient cases with simulated tumors in the head-and-neck region. For each case, treatment plans with and without intensity modulation were created for a uniform bolus and a range-modulating bolus. Treatment plans were evaluated using a target dose homogeneity index (HI), a conformity index (CI), the near-maximum dose outside the target ((Figure presented.)), and the near-minimum dose to the target ((Figure presented.)). Results: By adding intensity modulation to plans with a uniform bolus, the HI could be improved (p = 0.017). The combination of a range-modulating bolus and intensity modulation provided a further significant improvement of the HI as compared to using intensity modulation in combination with a uniform bolus (p = 0.036). The range-modulating bolus also improved the CI compared to using a uniform bolus, both with an open beam (p = 0.046) and with intensity modulation (p = 0.018), as well as increased the (Figure presented.) (p = 0.036 with open beam and p = 0.05 with intensity modulation) and reduced the median (Figure presented.) (not significant). Conclusions: By using intensity-modulated electron FLASH-RT in combination with range-modulating bolus, the target dose homogeneity and conformity in canine patients with simulated tumors in complex areas in the head-and-neck region could be improved. By utilizing this technique, we hope to decrease the dose outside the target volume and avoid hot spots in future clinical electron FLASH-RT studies, thereby reducing the risk of radiation-induced toxicity.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

conformity
electrons
FLASH
homogeneity
treatment planning

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy