SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:32b07629-bb82-4dae-8af1-f41df2ac9962"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:32b07629-bb82-4dae-8af1-f41df2ac9962" > A Statistical DOI E...

A Statistical DOI Estimation Algorithm for a SiPM-Based Clinical SPECT Insert

DrAdda, Ilenia (författare)
Polytechnic University of Milan
Morahan, Ashley J. (författare)
University College London
Carminati, Marco (författare)
Polytechnic University of Milan
visa fler...
Erlandsson, Kjell (författare)
University College London
Ljungberg, Michael (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Nuclear Medicine Physics,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Lund University Research Groups
Hutton, Brian F. (författare)
University College London
Fiorini, Carlo (författare)
Polytechnic University of Milan
visa färre...
 (creator_code:org_t)
2022
2022
Engelska.
Ingår i: IEEE Transactions on Radiation and Plasma Medical Sciences. - 2469-7311. ; 6:7, s. 771-777
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A prototype clinical brain SPECT insert has been designed for use in simultaneous SPECT/MRI. The system utilises novel slit-slat collimators which, like pinhole collimators, suffers from parallax errors due to the large incident angle of photons. A statistical algorithm has been developed to determine the depth-of-interaction (DOI) with a view to improving image performance. The importance of DOI correction was demonstrated using Monte Carlo simulation. This simulation also indicated that 4 DOI layers (3×1.5 mm+3.5 mm) may be sufficient. The improvement in event localisation was demonstrated on a single detector before implementing the algorithm on the full clinical prototype where some limitations in event localisation in layers close to the readout plane were observed. Nevertheless DOI enabled the rejection of poorly localised events with improved resolution in reconstructed line sources.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Biomedical imaging
Calibration
Collimators
depth-of-interaction
Detectors
event localisation.
Image reconstruction
Plasmas
Single photon emission computed tomography
SPECT

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy